ABB Tmax/Emax Circuit Breaker Fault Codes - Ekip Trip Indicators

⚡ Quick Answer

ABB Tmax and Emax 2 faults cover long-time overload, short-time trip, ground fault, overtemperature, phase loss, and Ekip communication.

⚡ AT A GLANCEScroll down for full repair guide
What it meansABB Tmax and Emax 2 faults cover long-time overload, short-time trip, ground fault, overtemperature, phase loss, and Ekip communication.
Most likely causeMost abb faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededCooling fan
Repair intent

Need this fixed instead of diagnosed?

ABB Tmax and Emax 2 faults cover long-time overload, short-time trip, ground fault, overtemperature, phase loss, and Ekip communication.

Likely parts to price

Price the common parts before you book service.

Cooling fan

Common VFD, drive, UPS, and cabinet overheating failure point.

Control keypad

Useful to price when faults involve display, keypad, or operator-panel behavior.

Fuses

Low-cost first check for power-stage and line-side faults.

Braking resistor

Price this on drive overvoltage, braking, or deceleration faults.

ABB Circuit Breaker Fault Codes - Quick Reference

ABB Tmax (T4, T5, T6, T7) and Emax 2 air circuit breakers use Ekip trip units (G, M, Hi, E series) that display fault history via LED indicators, Ekip Com modules, and the ABB Electrical Systems software.

Fault / LEDMeaningQuick Fix
LT LEDLong-time overload tripCheck load current, reduce if needed
ST LEDShort-time delay tripFind and clear downstream fault
I LEDInstantaneous tripInspect load circuit for fault
G LEDGround fault tripLocate earth fault
OT LEDOvertemperature tripCheck breaker cooling and load
COM FaultEkip Com module communication lostCheck wiring and module
Maintenance RequiredTrip counter at limitInspect breaker contacts
Phase LossMissing phase detectedCheck supply and bus connections
Ekip: Test TripManual test resultReset and close normally
ZSI ActiveZone interlock engagedCheck ZSI wiring and downstream breaker

Most Common Faults

Long-Time Overload (LT)

Ekip trip units record fault current and duration. Use the Ekip View software (via USB or Ekip Com) to read the trip log and verify actual fault current. If fault current is below rated load current, check the Ekip LT threshold (Ir) and time settings - factory defaults may not match your installation.

Instantaneous Trip (I)

ABB Emax 2 instantaneous trips indicate fault current above the Ii threshold, typically a bolted fault or severe cable insulation failure. After the breaker opens, inspect all load-side cables with a megohmmeter before re-energizing.

Ground Fault (G)

Ekip Hi and E trip units include sensitive ground fault protection. On systems with long cable runs, capacitive leakage current can cause nuisance ground fault trips. Adjust the Ig setting if leakage is confirmed to be capacitive rather than resistive.

COM Fault

The Ekip Com module provides Modbus, PROFIBUS, or BACnet connectivity. Loss of communication is usually caused by a loose connector, damaged RS-485 cable, or incorrect baud rate/address settings. Check the DIP switches on the Ekip Com module.

Parts Often Needed

PartNotes
Ekip trip unitReplace on electronics failure
Ekip Com moduleReplace on communication fault
Arc chutesReplace after multiple fault trips
Auxiliary contact blocksReplace on worn contacts
Undervoltage release (UVR)Replace on no-trip-open fault

Need Replacement Parts?

Before ordering, match the commercial equipment part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

ABB circuit breaker contact inspection and Ekip calibration require qualified electrical personnel. Do not reset after an instantaneous trip without verifying the load circuit is fault-free.