Skip to content
Industrial Error Code Fixes
Go back

Samsung Mini-Split E1-01 Error Code — Causes & Fix

⚡ Quick Answer

What Samsung mini-split E1-01 means, why the outdoor temperature sensor faults, and how to fix it.

⚡ AT A GLANCEScroll down for full repair guide
What it meansWhat Samsung mini-split E1-01 means, why the outdoor temperature sensor faults, and how to fix it.
Most likely causeMost mini-split faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
Repair time10-45 minutes for basic checks
Repair intent

Need this fixed instead of diagnosed?

What Samsung mini-split E1-01 means, why the outdoor temperature sensor faults, and how to fix it.

Samsung Mini-Split E1-01 Error Code — What It Means

E1-01 on a Samsung mini-split (Wind-Free, AR series, and multi-zone systems) indicates an outdoor air temperature sensor fault. The control board is receiving a signal from the outdoor ambient temperature sensor that is outside the valid range — either an open circuit (sensor disconnected or broken) or a short circuit (sensor shorted). Samsung uses thermistor-type temperature sensors; the board compares the sensor resistance to a known curve and flags E1-01 when the reading is invalid.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Locate the outdoor temperature sensor — On Samsung outdoor units, the ambient temperature sensor is typically clipped to the intake area of the outdoor coil or mounted near the top of the outdoor unit chassis. It is a small probe with a 2-wire lead.
  2. Inspect the sensor and connector — With power off, check the sensor connector on the outdoor control board for corrosion, bent pins, or a loose fit. Reseat the connector firmly.
  3. Test sensor resistance — Disconnect the sensor from the board. Using a multimeter on resistance (ohms) mode, measure across the sensor leads. At room temperature (20–25°C), most Samsung thermistors read approximately 10–12 kΩ. Open circuit (OL) or near-zero (short) = replace the sensor.
  4. Inspect the sensor wire — Trace the wire from the sensor to the board. Look for pinched, chewed, or cracked insulation. Repair or replace if damaged.
  5. Clear the fault and test — After replacing the sensor or reseating the connector, restore power and power cycle the outdoor unit. Verify E1-01 does not return.

Parts Often Needed

PartNotes
Outdoor ambient temperature sensorSamsung OEM; 10 kΩ NTC thermistor; match connector
Sensor harness/extension wireIf wire run is damaged
Outdoor control boardOnly if sensor input circuit is confirmed failed on the board

Need Replacement Parts?

Finding the right replacement parts for your equipment is critical to getting it running again. Check current prices on Amazon — prices and availability change frequently.

When to Call a Pro

If sensor and wiring check out but E1-01 persists, the outdoor control board’s sensor input circuit may need component-level repair or board replacement. A Samsung-authorized technician can access fault logs and confirm the board diagnosis.


Need a professional? Compare certified HVAC repair options before replacing parts.
Get Repair Quotes
Share this post on:

Previous Post
Rinnai Error Code 32 — Causes & Fix
Next Post