Skip to content
Industrial Error Code Fixes
Go back

Samsung Mini-Split E5-01 Error Code — Outdoor Coil Sensor Fault

⚡ Quick Answer

Samsung mini-split error code E5-01 means the outdoor coil temperature sensor is faulty. Learn causes, diagnostic steps, and how to fix Samsung E5-01.

Samsung Mini-Split Error Code E5-01 — Outdoor Coil Sensor Fault

Error Code E5-01 on Samsung mini-split systems means the outdoor heat exchanger (coil) temperature sensor has failed or is reading an out-of-range value. The outdoor unit control board cannot monitor the coil temperature required for defrost and system protection, so it shuts down.

Jump to Fix

Understanding Samsung’s Error Code Format

Samsung mini-splits use an E#-## format:

Other E5 variants:

What Is the Outdoor Coil Sensor?

The outdoor coil sensor monitors the temperature of the outdoor heat exchanger coil. In heat pump mode, it signals defrost initiation. In cooling mode, it helps detect refrigerant issues. It is typically a small NTC thermistor mounted in a clip directly on the coil tube.

Common Causes {#most-likely-cause}

CauseLikelihood
Failed outdoor coil sensorVery High
Sensor pulled out of coil clipHigh
Wiring harness loose at PCBHigh
Damaged sensor wire (pinched or corroded)Medium
Outdoor PCB analog input faultLow

Step-by-Step Diagnosis {#diagnosis}

Step 1 — Locate the sensor

Step 2 — Check the wiring connector

Step 3 — Measure sensor resistance Samsung outdoor coil sensors are NTC thermistors:

Step 4 — Check the PCB input

Replacement Parts {#parts}

PartNotes
Outdoor coil temperature sensorAmazon | Samsung OEM — match model (10K or 15K NTC)
Sensor mounting clipAmazon | Small plastic clip on coil tube — check it’s intact
Outdoor PCBAmazon | Only if sensor swap doesn’t clear the fault

Reset Procedure

After replacing the sensor:

  1. Reconnect all wiring
  2. Restore power to the outdoor unit
  3. E5-01 should clear on the first startup attempt
  4. Verify by running a cooling cycle and monitoring outdoor coil temperature via the service menu (if available)

Pro tip: Samsung mini-split sensor resistance tables are included in the installation manual. Download the manual for your model from the Samsung HVAC partner portal — it lists resistance at multiple temperatures for accurate field diagnosis.


🔧 Need a professional? Get free quotes from certified HVAC contractors near you.
Get Free Quotes →
Share this post on:

Previous Post
Rinnai Error Code 65 — Water Flow Rate Fault
Next Post
Siemens Micromaster 440 Fault F002 — Overcurrent