Noritz NR111 Tankless Water Heater Error Codes

The Noritz NR111 is a high-capacity condensing tankless water heater (199,000 BTU/hr). Error codes display on the front panel LED/LCD. Codes can also be read via the Noritz app or EZ Link cascading controller.

NR111 Error Code Table

CodeFault DescriptionCommon CauseAction
10Combustion issueVent blockage or combustion air faultInspect all vent terminations
11Ignition failureNo gas, spark, or flame sensorCheck gas pressure and electrode
12Flame loss mid-cycleUnstable gas pressureCheck gas supply and regulator
14Thermal fuseOverheating eventCheck heat exchanger flow and venting
16High temp limitScale, low flow, or sensor faultFlush HX, verify flow rate
20Thermistor AOutlet sensor failureReplace outlet sensor
21Thermistor BHeat exchanger sensor faultReplace HX sensor
29Fan motorFan motor failure or wiringCheck fan RPM and amps
31Combustion failureGas valve or electrodeCheck gas valve output
33Thermistor CInlet sensor faultReplace inlet sensor
52Gas valve modulationGas valve or PCB issueCheck valve coil resistance
61Combustion fanFan motor failureCheck fan rotation and amps
65Flow sensorLow flow or debrisCheck inlet screen and sensor
71Gas valve errorFailed gas valveReplace gas valve
90Combustion problemPCB or combustion air issueCheck combustion air and PCB

Most Common NR111 Faults

Code 11 ΓÇö Ignition Failure

NR111 requires minimum 3.5 in. w.c. gas pressure (natural gas) at the inlet. Verify full gas pressure with a manometer. Check igniter electrode condition and gap. Clean flame sensor rod with emery cloth.

Code 16 ΓÇö High Temperature Limit

In hard water regions, scale builds rapidly in NR111’s stainless heat exchanger. The unit will overheat at lower flow rates as heat transfer degrades. Descale with citric acid solution annually. Also verify minimum flow rate (0.75 GPM).

Code 65 ΓÇö Flow Sensor Fault

The NR111 flow sensor activates the burner when demand exceeds 0.75 GPM. A clogged inlet screen or debris from corroded pipes can restrict flow and prevent activation. Remove and clean the screen and sensor turbine.

Code 90 ΓÇö Combustion Problem

Code 90 is logged when the unit detects repeated combustion failures not attributed to a specific sensor. Check combustion air supply, verify CO2 percentage in flue gas (should be 8ΓÇô9.5% natural gas), and check PCB.

Parts Commonly Needed

PartNotes
Thermistor sensorsAmazon | Check resistance vs. chart
Flow sensorAmazon | Clean turbine before replacing
Igniter/flame rodAmazon | Check gap: 3.5ΓÇô4mm
Gas valveAmazon | Test coil resistance (8–12 Ω typical)
Fan motorAmazon | Match model voltage and RPM
Heat exchangerAmazon | Last resort ΓÇö descale first

Pro tip: Noritz NR111 units in cascade configurations (up to 16 units) can be monitored via the EZ Link controller. Fault codes for all units display on the controller ΓÇö check here before visiting individual units.