Skip to content
Error Code Fixes

Hitachi WJ200 / WL200 VFD Fault Codes Guide

1 min read

Hitachi WJ200 / WL200 Fault Codes

Hitachi WJ200 and WL200 drives are common on pumps, fans, and light machinery. Their fault list centers on current, voltage, thermal, and memory protection.

Common Hitachi Faults

FaultMeaningQuick Fix
E01Overcurrent at constant speedCheck load and motor wiring
E02Overcurrent during decelLengthen decel time
E03Overcurrent during accelLengthen accel time
E05Overload protectionCheck motor FLA and load
E07OvervoltageIncrease decel time
E08EEPROM/CPU faultPower cycle, replace drive if persistent
E09UndervoltageCheck line voltage
E12External tripCheck fault input terminal
E13Ground faultTest motor and leads
E14OvertemperatureClean cooling path, check fan

Best First Checks

  1. Inspect motor leads for insulation damage
  2. Verify nameplate motor data entered correctly
  3. Check if fault occurs on accel, decel, or run — that narrows the cause fast
  4. Clean the heatsink and fan path

Bottom Line

Hitachi faults usually tell you when in the motion profile the problem occurred. Use that clue — accel faults, decel faults, and run faults point to different fixes.

Need this fixed instead? Describe the fault — we'll route it.

Tell us the machine and what it's doing. We read every request and reply by email. Your details go only to our dispatch inbox — see the privacy policy.

Replies come by email. Your details go only to our dispatch inbox — no account, no list.



Previous Post
Henny Penny Fryer Error Codes — Guide
Next Post
Honeywell VisionPRO / T6 FC Fault — Fan Control Error