Skip to content
Industrial Error Code Fixes
Go back

ABB ACS355 Fault Codes - Complete Drive Troubleshooting Guide

⚡ Quick Answer

ABB ACS355 fault code guide covering 2310, 2330, 3130, 3180, 3210, 3220, 4110, 7121, and common machinery drive faults.

⚡ AT A GLANCEScroll down for full repair guide
What it meansABB ACS355 fault code guide covering 2310, 2330, 3130, 3180, 3210, 3220, 4110, 7121, and common machinery drive faults.
Most likely causeMost vfd faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
Repair time10-45 minutes for basic checks
Repair intent

Need this fixed instead of diagnosed?

ABB ACS355 fault code guide covering 2310, 2330, 3130, 3180, 3210, 3220, 4110, 7121, and common machinery drive faults.

ABB ACS355 Fault Codes - What They Mean

The ABB ACS355 is a machinery drive used on conveyors, pumps, fans, mixers, and OEM equipment. ACS355 fault codes identify the protection function that stopped the drive. The fastest path is to separate supply faults, motor/cable faults, thermal faults, and internal drive faults before replacing parts.

Jump to Fix

Common ACS355 Fault Codes

CodeMeaningFirst Check
2310OvercurrentJammed load, shorted motor cable, fast acceleration
2330Earth faultMotor insulation and cable damage
2340Short circuitMotor leads and output terminals
2381IGBT overloadMotor cable, switching stress, output fault
3130Input phase lossInput fuses, missing phase, voltage imbalance
3180Charge relay lostInternal charge circuit or relay feedback
3181Cross connectionInput and motor leads wired to wrong terminals
3210DC bus overvoltageDecel ramp, regen load, braking resistor
3220DC bus undervoltageIncoming supply, contactor, line sag
4110Drive overtemperatureCooling fan, heatsink, cabinet heat
7121Motor stallLocked load, wrong motor data, torque limit

Step-by-Step Fix

  1. Record the exact code. Do not troubleshoot “ABB fault” in general. The ACS355 code points to a specific protection group.
  2. Decide when the fault happens. Power-up faults usually involve wiring, supply, or internal hardware. Run-command faults often involve motor cable, motor, tuning, or load.
  3. Check line power first. For 3130 or 3220, measure all input phases at the drive under load. Inspect fuses, disconnects, contactors, and loose terminals.
  4. Test the motor circuit. For 2310, 2330, 2340, and 2381, isolate the motor and cable. Test insulation and winding balance before replacing the ACS355.
  5. Inspect cooling. For 4110, clean the heatsink path, verify the fan, and check cabinet temperature after the door is closed.
  6. Review motor data and ramps. Wrong motor rated current, aggressive acceleration, or too-short deceleration can create repeat faults.
  7. Retest with a controlled start. After repair, reset the drive and run the same load condition while monitoring current and DC bus voltage.

ACS355 3130 Quick Fix

Fault 3130 means input phase loss. Start with the upstream fuses, then measure L1-L2, L2-L3, and L1-L3 at the drive. If one phase is low or missing, fix the supply before resetting the drive.

Parts Often Needed

PartNotes
Input fusesCommon cause of 3130
Motor cableCommon cause of 2330 and 2340
Cooling fanCommon cause of 4110 in dusty cabinets
Braking resistorHelps with 3210 during fast deceleration
Replacement ACS355Consider for 3180 or repeat output faults with motor disconnected

Need Replacement Parts?

Finding the right replacement parts for your equipment is critical to getting it running again. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

Call a qualified electrician or drive technician for any fault that requires live three-phase measurement, insulation testing, or internal drive diagnosis. Stored DC bus voltage inside the ACS355 can remain dangerous after power is removed.

Source Notes


Need a professional? Compare certified Industrial repair options before replacing parts.
Get Repair Quotes
Share this post on:

Next Post
Allen-Bradley PowerFlex 755 F12 Fault - Hardware Overcurrent Fix