Yaskawa Encoder Cable
Replacement shielded encoder cable for Sigma-5 servomotors to resolve communication alarms like A.C90.
Diagnose and clear Yaskawa Sigma-5 SGDV SERVOPACK alarm codes. This guide covers A.100, A.300, A.400, A.510, A.710, A.C90, and other common faults.
Parts to price first
Replacement shielded encoder cable for Sigma-5 servomotors to resolve communication alarms like A.C90.
Replacement battery to maintain position data for absolute encoders and clear A.Eb0 alarms.
Replacement cooling fan for the SERVOPACK heatsink to prevent A.7A0 overheating alarms.
Complete replacement SERVOPACK drive module for critical hardware failures.
The full OEM-style workshop manual has the wiring diagram, test values, and the fault table this guide summarizes. Instant PDF download.
Diagnose and clear Yaskawa Sigma-5 SGDV SERVOPACK alarm codes. This guide covers A.100, A.300, A.400, A.510, A.710, A.C90, and other common faults.
Yaskawa Sigma-5 (SGDV) SERVOPACKs provide high-precision motion control, but an alarm code can stop a machine instantly. This guide provides clear, actionable steps for troubleshooting the most common alarm codes, helping you minimize downtime and get your equipment running safely.
Source: Yaskawa AC Servo Drives Σ-V Series User’s Manual, Document SIEP S800000 45, Chapter 10. A copy is available at https://www.yaskawa.com/downloads/search-downloads?search=SIEP%20S800000%2045
When a SERVOPACK detects a problem, it trips and displays an alarm code on its built-in digital operator or passes it to the host controller. The code starts with an “A.” and points to a specific fault condition. These alarms range from simple parameter issues to critical hardware faults. Understanding them is the key to a fast diagnosis.
| Code | Meaning |
|---|---|
| A.020 | Parameter Checksum Error |
| A.030 | Main Circuit Detector Error |
| A.040 | Parameter Setting Error |
| A.100 | Overcurrent or Heat Sink Overheated |
| A.300 | Regeneration Error |
| A.320 | Regenerative Overload |
| A.400 | Overvoltage |
| A.410 | Undervoltage |
| A.510 | Overspeed |
| A.710 | Overload (High Load) |
| A.720 | Overload (Low Load) |
| A.7A0 | Heat Sink Overheat |
| A.C10 | Encoder Overheat |
| A.C80 | Absolute Encoder Error |
| A.C90 | Encoder Communications Error |
| A.d00 | Position Error Overflow |
| A.E50 | Tracking Error |
| A.Eb0 | Absolute Encoder Battery Alarm |
A.100 (Overcurrent): This is a critical fault indicating that excessive current flowed through the drive’s output. The most common cause is a short circuit in the motor power cable (U, V, W phases) or a short to ground. It can also be caused by a faulty motor winding.
A.400 (Overvoltage): Occurs when the DC bus voltage inside the SERVOPACK exceeds its limit. This typically happens during rapid deceleration, where the motor’s inertia generates voltage back into the drive. Incorrect deceleration settings or a missing or faulty external regenerative resistor are the primary causes.
A.710 / A.720 (Overload): These alarms mean the motor was drawing more than its rated current for an extended period. A.710 indicates a short, high-level overload, while A.720 indicates a longer, lower-level overload. Look for mechanical binding, a load that is too heavy for the motor, or incorrect tuning (gain) parameters.
A.C90 (Encoder Communications Error): The SERVOPACK cannot communicate with the motor’s encoder. This is almost always caused by a damaged, disconnected, or incorrectly wired encoder cable. Electrical noise can also interfere with the signal.
A.d00 (Position Error Overflow): The difference between the commanded position and the actual motor position has exceeded the limit set in parameter Pn520. This can be caused by the motor stalling against a hard stop, a mechanical failure (like a broken belt), or tuning settings that are too aggressive for the load.
A.Eb0 (Absolute Encoder Battery Alarm): This alarm indicates that the battery for the absolute encoder has failed or is disconnected. The absolute position data has been lost.
Step 1: Identify and Record the Alarm. Note the full alarm code from the operator display. Use the operator to check the alarm history (Utility Function Fn000) for any previous faults that might be related. Do not immediately reset the alarm.
Step 2: Inspect Motor Wiring (A.100). For an overcurrent alarm, immediately power down the machine. Disconnect the motor power cable from the SERVOPACK terminals (U, V, W). Use a megohmmeter to check for shorts between phases and from each phase to ground. Inspect the entire length of the cable for damage.
Step 3: Check Regenerative Resistor (A.300, A.320, A.400). Ensure an external regenerative resistor is properly connected to the B1 and B2 terminals if required by your application. Check the wiring and measure the resistor’s resistance to ensure it matches specifications. For overvoltage alarms, try increasing the deceleration ramp time in your motion controller.
Step 4: Verify Mechanical Load (A.710, A.720, A.d00). Check the machine for any signs of mechanical binding, collisions, or blockages. Disengage the motor from the load if possible and try to move the mechanics by hand to feel for resistance. An unexpected jam will cause both overload and position error alarms.
Step 5: Inspect Encoder Cable (A.C90). For any encoder-related alarm, the cable is the first suspect. Power down the system and carefully inspect the encoder cable at both the motor and SERVOPACK ends. Check for bent pins, loose connectors, or signs of physical damage. If possible, test with a known good cable.
Step 6: Replace Encoder Battery (A.Eb0). If you receive a battery alarm, power down the system and replace the battery connected to the absolute encoder. After replacement, you will need to re-home the machine or reset the absolute encoder origin using Utility Function Fn008.
Step 7: Reset the Alarm. Once you have identified and corrected the likely cause, you can reset the alarm by cycling power, using the external ALM-RST input, or via software. If the alarm returns immediately, there is likely a hardware failure in the SERVOPACK or motor.
Encoder Cable: These are complex, multi-wire shielded cables that can fail from repeated flexing or physical damage. Having a spare is highly recommended for critical machines.
Encoder Battery: For systems with absolute encoders, the battery is a consumable part that needs to be replaced periodically to avoid losing position data.
Regenerative Resistor: If a machine is retrofitted for faster cycle times, the original regenerative capacity may be insufficient, requiring a larger external resistor to handle the increased braking energy.
If you have confirmed the motor and cabling are good but an A.100 overcurrent alarm persists, the SERVOPACK’s internal power stage has likely failed. This requires replacing the drive.
For alarms like A.030 (Main Circuit Detector Error) or other internal hardware faults, the SERVOPACK needs to be repaired or replaced by a qualified technician.
If you are struggling with complex tuning issues that lead to overload or position error alarms, a controls engineer with experience in servo systems can help optimize your gain parameters and motion profiles.
Alarm A.100 is an overcurrent alarm. It means too much current flowed through the drive's power transistors (IGBTs). This is often caused by a short circuit in the motor wiring or a grounded motor winding. Always check motor cables before resetting this alarm.
The A.400 alarm indicates the DC bus voltage is too high, usually from rapid deceleration. The motor is acting like a generator and sending too much power back to the drive. The fix is to either increase the deceleration time or install an external regenerative resistor to dissipate the excess energy.
A.710 is a high-load overload alarm. It means the motor has been running under a load that exceeds its rated torque for several seconds. You need to check for mechanical binding, incorrect gain settings (rigidity), or an undersized motor for the application.
You can reset most alarms by cycling power to the SERVOPACK, using the 'Alarm Reset' input signal (wired to the CN1 connector), or via the digital operator using utility function Fn000. Note that some critical alarms like A.100 cannot be reset until power is cycled.