Sullair Air Filter Element
Intake air filter for high temperature faults and reduced capacity; match compressor model number and change every 2000 hours or annually.
Sullair rotary screw compressor fault codes and alarms for Supervisor and Touch Panel controllers: causes, fixes, and parts.
Parts to price first
Intake air filter for high temperature faults and reduced capacity; match compressor model number and change every 2000 hours or annually.
Separator element for high pressure differential and oil carryover faults; critical service item every 4000-8000 hours depending on conditions.
Oil filter for low oil pressure and temperature faults; change at every oil service interval per Sullair maintenance schedule.
Synthetic lubricant for Sullair rotary screw compressors; prevents high temperature trips and extends bearing life, 8000-hour service interval.
Replacement temperature sensor for high temp fault or sensor error codes; verify thread size and resistance spec before ordering.
Minimum pressure valve for separator element damage and low pressure faults; maintains back pressure to protect separator and prevent oil loss.
The full OEM-style workshop manual has the wiring diagram, test values, and the fault table this guide summarizes. Instant PDF download.
Generic-equivalent control relays, limit and pressure switches, solenoids, bearings, and fuses when the OEM part number is backordered.
Sullair rotary screw compressor fault codes and alarms for Supervisor and Touch Panel controllers: causes, fixes, and parts.
Sullair rotary screw compressors use the Supervisor and Touch Panel controllers to display warning and shutdown alarms. Codes vary by model (S-Series, 900/1150 HH, ShopTek), but these are the most common alarm families.
| Fault | Meaning | Quick Fix |
|---|---|---|
| High Discharge Temperature | Outlet air/oil temp exceeds limit | Check coolers, oil level, ambient temp |
| Low Oil Pressure | Lubrication fault | Check oil level, filter, pump |
| High Oil Temperature | Oil overheating | Check oil cooler, oil quality |
| Motor Overload | Drive motor overcurrent | Check amps, voltage, load |
| E-Stop Active | Emergency stop tripped | Reset E-stop, inspect circuit |
| Service Required | PM interval reached | Perform scheduled service |
| Separator Differential High | Oil separator restricted | Replace separator element |
| High Sump Pressure | Sump pressure relief or blowdown fault | Check minimum pressure valve |
| Sensor Fault | Temp or pressure sensor out of range | Check wiring and sensor |
| Blowdown Fault | Blowdown valve not opening | Inspect blowdown valve |
The leading cause of Sullair shutdowns. Dirty oil cooler fins, low oil level, high ambient temperature, or a failed cooling fan all drive this fault. Start with cleaning the cooler with dry air blown against normal airflow. Check oil level when cool. Verify fan operation.
A restricted oil separator causes high pressure drop and oil carryover into the discharge air. Replace the separator element at or before the rated service interval. On Sullair units this is typically 2,000–4,000 hours depending on model.
Check the oil level first - if low, fill and reset. If oil level is correct, the oil filter may be bypassing or the scavenge line may be blocked. On older units, the oil pump pickup can become contaminated.
Verify incoming voltage balance on all three phases. Unbalanced voltage causes disproportionate current draw on one phase and will trip the overload even at normal load. Also check the inlet valve if the compressor loads too heavily on startup.
| Part | Notes |
|---|---|
| Air/oil separator element | Replace every 2,000–4,000 hours |
| Oil filter | Replace with separator service |
| Discharge temperature sensor | Common on high-hour units |
| Inlet valve kit | Common cause of motor overloads |
| Minimum pressure valve | Fails open causing high sump pressure |
Before ordering, match the commercial equipment part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Repeated discharge temperature trips after cleaning, or loss of oil pressure with correct oil level, indicate internal airend wear or oil pump failure. These require disassembly and should be handled by a Sullair-trained technician.
High temp faults come from clogged coolers, low oil level, failed thermostatic valve, dirty air filter, or ambient temperature above rated specs. Check oil level first, then inspect cooler fins and air filter condition.
Air filter every 2000 hours or 1 year, oil filter and oil every 4000-8000 hours depending on synthetic vs mineral oil, separator element every 4000-8000 hours. Dirty environments need more frequent service.
Motor overload trips from high discharge pressure, failed unloader valve, restricted separator, low voltage, or mechanical binding in the airend. Check separator pressure differential and unloader operation first.
You can reset most faults, but the controller will trip again if the underlying condition persists. Some faults require manual reset at the controller. Repeated resets without diagnosis damage the compressor and void warranty.