Sullair Air Compressor Fault Codes - Complete Guide

⚡ Quick Answer

Sullair rotary screw compressor fault codes and alarms for Supervisor and Touch Panel controllers: causes, fixes, and parts.

Sullair Compressor Fault Codes - Quick Reference

Sullair rotary screw compressors use the Supervisor and Touch Panel controllers to display warning and shutdown alarms. Codes vary by model (S-Series, 900/1150 HH, ShopTek), but these are the most common alarm families.

FaultMeaningQuick Fix
High Discharge TemperatureOutlet air/oil temp exceeds limitCheck coolers, oil level, ambient temp
Low Oil PressureLubrication faultCheck oil level, filter, pump
High Oil TemperatureOil overheatingCheck oil cooler, oil quality
Motor OverloadDrive motor overcurrentCheck amps, voltage, load
E-Stop ActiveEmergency stop trippedReset E-stop, inspect circuit
Service RequiredPM interval reachedPerform scheduled service
Separator Differential HighOil separator restrictedReplace separator element
High Sump PressureSump pressure relief or blowdown faultCheck minimum pressure valve
Sensor FaultTemp or pressure sensor out of rangeCheck wiring and sensor
Blowdown FaultBlowdown valve not openingInspect blowdown valve

Most Common Faults

High Discharge Temperature

The leading cause of Sullair shutdowns. Dirty oil cooler fins, low oil level, high ambient temperature, or a failed cooling fan all drive this fault. Start with cleaning the cooler with dry air blown against normal airflow. Check oil level when cool. Verify fan operation.

Separator Differential High

A restricted oil separator causes high pressure drop and oil carryover into the discharge air. Replace the separator element at or before the rated service interval. On Sullair units this is typically 2,000–4,000 hours depending on model.

Low Oil Pressure

Check the oil level first - if low, fill and reset. If oil level is correct, the oil filter may be bypassing or the scavenge line may be blocked. On older units, the oil pump pickup can become contaminated.

Motor Overload

Verify incoming voltage balance on all three phases. Unbalanced voltage causes disproportionate current draw on one phase and will trip the overload even at normal load. Also check the inlet valve if the compressor loads too heavily on startup.

Parts Often Needed

PartNotes
Air/oil separator elementAmazon | Replace every 2,000–4,000 hours
Oil filterAmazon | Replace with separator service
Discharge temperature sensorAmazon | Common on high-hour units
Inlet valve kitAmazon | Common cause of motor overloads
Minimum pressure valveAmazon | Fails open causing high sump pressure