BOGE Compressor Fault Codes List: Control and Select Alarm Meanings

⚡ Quick Answer

BOGE compressor fault codes for Control and Select panels: high temperature, filter DP, separator DP, motor overload, phase loss and sensor faults, with fixes.

⚡ AT A GLANCEScroll down for full repair guide
What it meansBOGE Control and Select alarms point to compressor temperature, filtration, oil separator, motor overload, sensor, phase, or service-interval faults.
Most likely causeMost shutdowns trace to dirty coolers, restricted filters or separators, low or degraded oil, motor load, bad feedback sensors, or supply phase problems.
First checkRead the exact display text, check cooler airflow and oil level, then compare filter DP, separator DP, motor current, and sensor readings before reset.
⏱Repair time10-30 minutes for checks; scheduled service time varies
🔧Part neededBOGE air filter oil separator temperature sensor fan capacitor pressure regulator solenoid

Parts to price first

Check the part before you book service.

BOGE air compressor filter kit

Match compressor series and service interval before replacing air, oil, or separator filters.

$45-$220Check price

Air compressor oil separator element

Use for separator differential-pressure faults after confirming the exact housing and element size.

$40-$220Check price

Compressor discharge temperature sensor

Compare probe type, thread, and wiring before replacing a discharge-temperature fault sensor.

$20-$120Check price

Cooling fan capacitor

Match microfarads and voltage before replacing a weak single-phase fan capacitor.

Compressor pressure regulator solenoid

Check coil voltage, valve movement, and regulator wiring before ordering for pressure-regulator faults.

$25-$160Check price

Equipment service manual download (eManualOnline)

The full OEM-style workshop manual has the wiring diagram, test values, and the fault table this guide summarizes. Instant PDF download.

Relays, switches, bearings, and fuses (Harfington MRO)

Generic-equivalent control relays, limit and pressure switches, solenoids, bearings, and fuses when the OEM part number is backordered.

Need a technician? Compare Industrial repair options before replacing parts.
Get a repair quote
Repair intent

Need this fixed instead of diagnosed?

BOGE compressor fault codes for Control and Select panels: high temperature, filter DP, separator DP, motor overload, phase loss and sensor faults, with fixes.

BOGE Compressor Fault Codes List - Quick Reference

Use this BOGE compressor fault codes list to match common BOGE Control and BOGE Select alarms to the first checks: cooling airflow, oil level, filter differential pressure, separator restriction, motor load, sensor wiring, and phase monitoring. Some controller generations show text alarms instead of short numeric codes, so match the exact display message before ordering parts.

Code / AlarmMeaningQuick Fix
High Final Pressure TempDischarge temp too highClean cooler, check oil
Low Oil PressureLube circuit faultCheck oil level and filter
Motor Overload (OL)Motor overcurrentCheck amps and phase balance
E-StopEmergency stop activeReset and inspect
Service IntervalPM duePerform service, reset counter
Air Filter Diff. HighAir filter blockedReplace air filter element
Oil Separator DPOil separator restrictedReplace separator element
Pressure Regulator FaultRegulator not maintaining set pointCheck regulator and solenoid
Phase MonitoringPhase loss or reversalCheck supply wiring
Temperature SensorSensor out of rangeCheck sensor wiring

Safety Before You Start

BOGE screw compressors combine line voltage, stored air pressure, and hot surfaces. Treat every fault investigation as work on live equipment until you have proven otherwise.

Tools You Will Need

Most Common Faults

High Final Pressure Temperature

BOGE screw compressors are sensitive to oil cooler cleanliness. The cooler fins on BOGE units pack densely and require cleaning from the inside out with compressed air or a fin brush.

  1. Confirm when the alarm appears: at startup, under steady load, or only after extended run time. This timing narrows down whether the cause is a cold-start issue or a cumulative heat buildup problem.
  2. With the unit stopped and cooled, check the oil level at the sight glass. Low oil reduces both lubrication and cooling capacity together, since oil carries heat away from the airend.
  3. Clean the cooler fins from the inside out with compressed air or a soft fin brush. Do not use a pressure washer directly on the fins, since this can bend the delicate fin structure and reduce airflow permanently.
  4. Verify the cooling fan capacitor on single-phase fan motors. A weak capacitor lets the fan spin but at reduced speed and torque, which is easy to miss on a casual visual check since the fan still appears to be running.
  5. Measure discharge temperature with an infrared thermometer at the airend outlet and compare it to the controller’s displayed value. A mismatch points to a sensor problem rather than an actual overheat.
  6. Check the compressor room’s ambient temperature and ventilation. BOGE units rated for standard ambient conditions will trip sooner in a hot, poorly ventilated room even with clean equipment.
  7. If oil, cooler, fan, and sensor readings all check out, the airend bearings or rotor clearances may be the source of extra heat generation, which requires professional inspection.

Air Filter Differential High

Some BOGE models have a differential pressure switch across the air filter. A clogged filter reduces airflow, increases velocity through the airend, and causes temperature rise.

  1. Depressurize the intake side if required by your model before removing the filter housing cover.
  2. Inspect the filter element for visible dust loading, oil contamination, or physical damage.
  3. Replace the filter element rather than attempting to clean and reuse it, since most BOGE air filter elements are not rated for cleaning and reinstalling.
  4. Check the intake area around the compressor for airborne dust sources that could be shortening filter life faster than the normal service interval.

Oil Separator DP

The separator element is a scheduled service part, typically rated for 3,000 to 4,000 hours depending on model and operating environment. In dusty environments or with degraded oil, it can plug much sooner.

  1. Fully depressurize the separator tank and confirm zero pressure before opening any fitting.
  2. Record the differential pressure reading on the controller display if available, or connect a manifold gauge across the separator inlet and outlet per the service manual.
  3. Replace the separator element. A high differential pressure across the separator increases power consumption noticeably before triggering the alarm, so continuing to run on a choked separator wastes energy even before it causes a shutdown.
  4. While the housing is open, inspect the oil scavenge line for kinks or blockage. A blocked scavenge line will choke a new separator element quickly and cause the alarm to return sooner than expected.
  5. After reinstalling, torque the separator housing cover to the spec in the BOGE service manual. Under-torqued covers can leak. Over-torqued covers can crack the housing or damage the seal.

Motor Overload (OL)

  1. Measure supply voltage at the compressor’s input terminals while it is running under load. Voltage sagging more than about 10 percent below nameplate forces the motor to draw extra current for the same output.
  2. Check phase balance on three-phase units by measuring voltage between each pair of phases. Imbalance beyond roughly 2 percent stresses the motor windings and can cause nuisance overload trips.
  3. Confirm nothing downstream is demanding more air than the compressor’s rated capacity, since sustained overdemand raises motor load continuously.
  4. Inspect the motor and its coupling or belt drive for binding, misalignment, or bearing wear that adds mechanical resistance.
  5. If voltage, phasing, and demand check out, have a qualified electrician confirm the overload relay setpoint matches the motor nameplate current and verify actual running current with a clamp meter.

Phase Monitoring

A phase loss or reversal alarm protects the motor from running on two phases or in the wrong rotation, either of which can cause rapid winding damage.

  1. With power locked out, inspect the incoming supply wiring and fuses or breaker for one blown fuse or a loose terminal on one leg.
  2. Restore power only after confirming the wiring is intact, then measure voltage on all three legs at the compressor’s input terminals.
  3. If one phase reads significantly lower or absent, the fault is upstream in the building’s electrical supply and needs an electrician, not compressor parts.
  4. If a phase reversal alarm appears after any electrical service work nearby, such as a panel swap or generator connection, check that phase rotation was not swapped during that work.

E-Stop

An E-Stop alarm means an emergency stop circuit is open, whether from the physical button, a door interlock, or a wired safety circuit.

  1. Physically inspect and reset the E-stop button, confirming it twists or pulls out fully to the reset position per its design.
  2. Check any door or guard interlock switches in the safety circuit for a door left ajar or a switch that has drifted out of alignment.
  3. If the alarm will not clear after confirming all physical E-stops and interlocks are reset, the safety relay or its wiring may have failed and needs professional diagnosis.

Parts Often Needed

PartNotes
Oil separator elementPrimary PM item
Air filter elementReplace per service schedule
Oil filterReplace with separator
Cooling fan capacitorCommon on single-phase fan motors
Discharge temperature sensorThermocouple or NTC type
Pressure regulator solenoidFor regulator faults after checks

Focused Parts Searches

Before ordering, match the compressor service part to the BOGE model, controller alarm, element size, and electrical rating.

When to Call a Pro

BOGE compressors require factory-specific oil types and torque specs on separator housing reassembly. Call a BOGE authorized service provider when:

Quick FAQ

Where can I find a BOGE compressor fault codes list?

Use the table below for common BOGE Control and BOGE Select alarms, including high final-pressure temperature, filter differential pressure, oil separator DP, motor overload, sensor faults, and phase monitoring.

What causes high final pressure temperature on a BOGE compressor?

High final pressure temperature is commonly caused by dirty cooler fins, low or degraded oil, poor airflow, or a weak cooling fan capacitor.

What does Air Filter Differential High mean on a BOGE compressor?

It means the controller sees too much pressure drop across the air filter. Replace the filter element and check intake airflow before restarting.

Why does a BOGE oil separator DP alarm matter?

A high separator differential pressure increases power consumption and can lead to shutdown. Replace the separator element with the correct part for the compressor model.


Share this post on: