Inlet air filter element
Part: Ingersoll-Rand 39708466 (match model)
Replace at the scheduled interval or when LOW INLET PRESSURE trips the differential switch.
Ingersoll-Rand R-Series rotary screw compressor fault codes and diagnostics. Fault codes, causes, and technician-level troubleshooting.
Parts to price first
Part: Ingersoll-Rand 39708466 (match model)
Replace at the scheduled interval or when LOW INLET PRESSURE trips the differential switch.
Part: Ingersoll-Rand 39329602 (match model)
Level 1 service item every 2,000 hours; also check after any OIL FAULT.
Part: Ingersoll-Rand 39831888 (match model)
Replace at the Level 2 interval or when oil carryover and separator differential rise.
Part: Ingersoll-Rand Ultra Coolant 38459582
IR synthetic lubricant; top up or change when HIGH TEMP traces to low or degraded oil.
Part: Ingersoll-Rand electronic drain valve
Replace when DRAIN FAULT shows the valve stuck open or closed.
Part: Ingersoll-Rand Intellisys thermistor
Match the Intellisys controller input type; replace on SENSOR FAULT after wiring checks.
The full OEM-style workshop manual has the wiring diagram, test values, and the fault table this guide summarizes. Instant PDF download.
Generic-equivalent control relays, limit and pressure switches, solenoids, bearings, and fuses when the OEM part number is backordered.
Ingersoll-Rand R-Series rotary screw compressor fault codes and diagnostics. Fault codes, causes, and technician-level troubleshooting.
Ingersoll-Rand R-Series rotary screw compressors (R7.5-R90) use the Intellisys controller for monitoring and fault management. Faults display on the Intellisys panel as text messages. The controller logs fault history with timestamps and run hours.
| Fault | Fault Description | Common Cause | Action |
|---|---|---|---|
| HIGH TEMP | High discharge temperature | Cooler dirty, low oil, high ambient | Clean cooler, check oil level |
| HIGH TEMP WARN | Temperature warning | Approaching shutdown threshold | Pre-clean cooler before shutdown |
| STAR DELTA FAULT | Starter transition fault | Contactor or timing issue | Check starter sequence |
| OVERLOAD | Motor overload trip | Motor overload or high current | Check motor amps and load |
| HIGH PRESSURE | Discharge pressure too high | Excessive demand or closed valve | Check discharge valve |
| LOW INLET PRESSURE | Inlet filter restricted | Dirty inlet filter | Replace inlet air filter |
| OIL FAULT | Low oil pressure | Low oil, failed oil pump | Check oil level and pump |
| PHASE FAULT | Phase loss or imbalance | Supply fault | Check input voltage |
| EMERGENCY STOP | E-stop activated | E-stop button pressed | Check E-stop circuit |
| SERVICE LEVEL 1 | Preventive maintenance due | Hours elapsed | Perform scheduled PM |
| SERVICE LEVEL 2 | Major PM due | Major service interval | Perform major PM |
| SENSOR FAULT | Temperature sensor failure | Failed thermistor | Replace temperature sensor |
| DRAIN FAULT | Auto-drain failure | Solenoid drain valve stuck | Check drain valve operation |
Ingersoll-Rand R-Series maximum discharge temperature is typically 235 degrees F (113 degrees C) for standard models. High temp shutdowns are almost always caused by dirty oil coolers or dirty air coolers. Blow cooler fins with low-pressure air or wash with coil cleaner. Check oil level with the unit loaded and running.
Check three-phase supply voltage and balance. A 5% voltage imbalance can cause 25%+ current imbalance. Reset the overload relay after determining the cause. Check unloader operation - if the unit is starting under load, motor current is excessive on startup.
Ingersoll-Rand R-Series inlet filters have a differential pressure switch that triggers this alarm when restriction is excessive. Check filter element - replace at the service interval or when restriction is detected. Do not operate the compressor with a dirty filter; accelerated airend wear results.
The Intellisys controller tracks service intervals by run hours. Level 1 is typically the oil filter and separator element interval (every 2,000 hours). Level 2 is the major service interval (airend inspection, oil change, full filter replacement). Perform maintenance and reset the service timer in the Intellisys menu.
| Part | Notes |
|---|---|
| Inlet air filter | Replace at scheduled interval |
| Oil filter element | IR-specific - match model |
| Oil separator element | Replace at Level 2 interval |
| Compressor oil | IR synthetic - model-specific |
| Auto-drain solenoid valve | Check for stuck-open or stuck-closed |
| Temperature sensor | Match Intellisys controller input type |
Before ordering, match the commercial equipment part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Pro tip: Ingersoll-Rand Intellisys controllers on networked compressor rooms can be monitored remotely via the IR Connect app. Fault alerts can be sent to maintenance personnel by email or text, enabling faster response to high-temperature events before the compressor shuts down.
Typically 235 degrees F (113 degrees C) for standard models. HIGH TEMP shutdowns are almost always caused by dirty oil coolers or air coolers, low oil level, or high ambient temperature.
Check three-phase supply voltage and balance first: a 5% voltage imbalance can cause a 25%+ current imbalance. Reset the overload relay only after finding the cause, and verify the unloader is working.
The Intellisys controller tracks service intervals by run hours. Level 1 is typically the oil filter and separator element interval, about every 2,000 hours. Level 2 is the major service interval that includes the airend inspection.
The inlet filter differential pressure switch triggers this alarm when restriction is excessive. Replace the inlet filter element at the service interval or whenever restriction trips the alarm.