Navien E006 Error Code — Causes & Fix

⚡ Quick Answer

What Navien error code E006 means, why the exhaust high limit trips, and how to fix it step by step.

E006 on a Navien tankless water heater or combi-boiler indicates the exhaust (flue) high-limit sensor detected temperatures above the safe threshold. The exhaust thermistor monitors flue gas temperature leaving the heat exchanger; if it reads above approximately 149°C (300°F), the unit shuts down to prevent damage to the PVC venting, the heat exchanger, or surrounding combustibles.

Jump to Fix

Common Causes

Step-by-Step Fix {#fix}

  1. Inspect the exhaust vent termination — Go outside and check the PVC exhaust cap. Clear any blockage, ice, or debris. For concentric vent systems, check both the exhaust and combustion air annulus.
  2. Check the exhaust thermistor — With power off, locate the exhaust temperature sensor (small probe near the flue outlet). Disconnect its connector and measure resistance with a multimeter. At room temperature (~25°C), most Navien exhaust thermistors read approximately 10 kΩ. Compare to the temperature-resistance chart in the service manual.
  3. Flush the heat exchanger — If the unit has been in service for more than 2–3 years in a hard water area, perform a descaling flush using white vinegar or Navien’s recommended descaling solution through the service valves.
  4. Check incoming gas pressure — Have a licensed gas technician measure manifold gas pressure at the unit. For natural gas, manifold pressure should be 3.5” WC; for propane, 10” WC (verify against unit nameplate).
  5. Clear E006 and test — After addressing the cause, reset the unit (press the Power button off and on, or hold Reset on NPE series units). Run a full demand cycle and confirm no E006 recurrence.

Parts Often Needed

PartNotes
Exhaust thermistorAmazon | Navien OEM; match to NPE or NCB model
Descaling kit (vinegar flush)Amazon | Use food-grade white vinegar; 1 gallon minimum
PVC vent cap (exhaust)Amazon | Replace if cracked or blocked by bird screen debris

When to Call a Pro

Gas pressure adjustment and heat exchanger descaling with chemical descalers should be performed by a licensed plumber or HVAC technician. Do not operate the unit with a confirmed blocked flue.