Skip to content
Industrial Error Code Fixes
Go back

LG Mini-Split CH26 Error Code — CT Sensor Fault

⚡ Quick Answer

LG mini-split CH26 error code means a current transformer (CT) sensor fault on the outdoor unit. Learn causes, diagnostic steps, and how to fix LG CH26.

⚡ AT A GLANCEScroll down for full repair guide
What it meansLG mini-split CH26 error code means a current transformer (CT) sensor fault on the outdoor unit. Learn causes, diagnostic steps, and how to fix LG CH26.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
Repair time10-45 minutes for basic checks
Repair intent

Need this fixed instead of diagnosed?

LG mini-split CH26 error code means a current transformer (CT) sensor fault on the outdoor unit. Learn causes, diagnostic steps, and how to fix LG CH26.

LG Mini-Split CH26 Error Code — CT Sensor Fault

Error Code CH26 on LG mini-split and multi-zone systems indicates a current transformer (CT) sensor fault on the outdoor unit. The CT sensor monitors the compressor current draw and is critical for inverter compressor protection. When the sensor fails or reads outside its expected range, CH26 is triggered.

Jump to Fix

What Is the CT Sensor?

The CT (current transformer) sensor is a small toroidal coil that clamps around the compressor supply wire. It measures compressor current without direct electrical contact. The outdoor PCB reads this signal to protect the compressor from overcurrent and to control inverter frequency.

Common Causes {#most-likely-cause}

CauseLikelihood
CT sensor failed or disconnectedVery High
CT sensor wiring harness loose or brokenHigh
Outdoor PCB analog input failureMedium
CT sensor mounted incorrectly (not around wire)Medium
Actual compressor overcurrent (compressor fault)Low

Step-by-Step Diagnosis {#diagnosis}

Step 1 — Locate the CT sensor

Step 2 — Check the connector

Step 3 — Measure CT sensor output

Step 4 — Check wiring

Step 5 — Verify compressor operation

Replacement Parts {#parts}

PartNotes
CT sensor (current transformer)LG OEM part — match model number
Outdoor PCBOnly replace after confirming sensor and wiring are good

Need Replacement Parts?

Finding the right replacement parts for your equipment is critical to getting it running again. Check current prices on Amazon — prices and availability change frequently.

Reset Procedure

  1. Repair or replace the CT sensor
  2. Confirm connector is fully seated
  3. Restore power and attempt restart
  4. CH26 clears automatically on a successful startup if the sensor reads correctly

Note: LG CH26 is sometimes confused with CH25 (compressor overcurrent). CH25 means the compressor actually drew too much current; CH26 means the measurement circuit itself has failed. The repair procedures are different — CH25 leads to the compressor, CH26 leads to the sensor.


Need a professional? Compare certified HVAC repair options before replacing parts.
Get Repair Quotes
Share this post on:

Previous Post
LG Mini-Split CH21 Error Code — Outdoor Unit High Pressure
Next Post
Mazak Alarm 700 — MPC Alarm