FLIR T620 Thermal Camera Error Codes: Complete Guide

⚡ Quick Answer

FLIR T620 thermal imaging camera error codes and fault messages. Error causes and technician-level troubleshooting for industrial thermography.

FLIR T620 Thermal Camera Error Codes

The FLIR T620 is a professional thermal imaging camera with a 640×480 uncooled microbolometer detector. Error messages display on the camera LCD or in the FLIR Tools software. Most errors relate to calibration, communication, or detector issues.

FLIR T620 Error Messages Table

MessageMeaningCauseAction
NUC in progressFlat field correctionAutomatic shutter calibrationNormal ΓÇö wait for completion
Battery lowLow batteryBattery depletedReplace or charge battery
SD card errorMemory card faultCorrupt or incompatible cardFormat or replace SD card
OvertempCamera overtemperatureHigh ambient temperatureAllow camera to cool
USB comm errorCommunication failureUSB driver or cable issueCheck USB cable and drivers
Image corruptFile system errorCorrupt image fileDelete file, check SD card
Focus errorAutofocus faultDirty lens or close rangeClean lens, check focus mode
Detector faultDetector initializationDetector or PCB failureContact FLIR service
FFC failedFlat-field correction failShutter mechanism faultReturn for service
GPS errorGPS module faultGPS antenna issueCheck GPS settings

Most Common FLIR T620 Issues

NUC In Progress

The T620 performs automatic Non-Uniformity Correction (NUC) using an internal shutter mechanism. This is normal operation and takes 1ΓÇô3 seconds. If the camera performs NUC excessively, it may indicate rapid ambient temperature changes. Allow the camera to reach thermal equilibrium before beginning thermographic surveys.

Battery Low

The T620 uses a 3.7V Li-ion smart battery (FLIR T197771 or equivalent). The battery charge indicator shows remaining percentage. In cold weather, battery performance decreases significantly ΓÇö carry a spare battery and keep it warm until needed.

SD Card Error

The T620 supports SDHC cards up to 32GB (FAT32 format). SDXC cards are not supported. If an SD card error occurs, format the card in-camera via Settings → Storage → Format Card. If errors persist, replace the card.

Detector Fault

A detector fault indicates a problem with the microbolometer array or its control PCB. This requires factory service. Do not attempt to disassemble the camera ΓÇö the detector requires a clean room environment.

FFC Failed ΓÇö Flat Field Correction

If the internal shutter mechanism fails, the camera cannot perform NUC. Symptoms include persistent fixed-pattern noise on the image. The shutter is a mechanical component that wears with use. Contact FLIR for shutter replacement.

Parts Commonly Needed

PartNotes
Battery packAmazon | FLIR T197771 or compatible
Battery chargerAmazon | FLIR ACC-T197773
SD cardAmazon | Class 10 SDHC up to 32GB, FAT32
Lens cleaning kitAmazon | Dry optical lens tissue only
USB cableAmazon | Mini-USB type B

Pro tip: FLIR T620 calibration is typically factory-verified annually. Keep calibration certificates current for compliance with industrial thermography standards (ISO 18436-7, ASNT TC-1A). Calibration expiry appears in FLIR Tools under camera properties.