ELGi Air Compressor Fault Codes Guide — Troubleshooting Alarms

⚡ Quick Answer

ELGi air compressor fault codes for EG, EN, and AB series: alarms, shutdown causes, and troubleshooting steps for rotary screw and reciprocating compressors.

ELGi Compressor Fault Codes — Quick Reference

ELGi compressors (EG, EN, AB series) use an electronic controller that monitors temperature, pressure, motor current, and maintenance intervals. Alarm messages appear on the display with a fault description and recommended action.

FaultMeaningQuick Fix
High Discharge TemperatureAir end outlet temp exceededCheck oil, cooler, fan
High Oil TemperatureOil circuit too hotClean oil cooler, check oil level
Low Oil PressureOil pressure dropped below setpointCheck oil level and filter
Motor OverloadMotor drew excess currentCheck voltage and demand
High PressureSystem pressure above limitCheck pressure switch and unloader
Air/Oil Separator ChokedSeparator element restrictedReplace separator element
Sensor FailureTemp or pressure sensor faultInspect sensor and harness
Service RequiredScheduled PM duePerform PM and reset counter

Most Common Faults

High Discharge Temperature

ELGi compressors are known for robust cooling systems but they still trip on high discharge temp when oil is low, coolers are dirty, or ambient temperature is excessive. Begin with the oil sight glass — ensure oil is at the correct level when the machine is stopped. Clean the oil cooler core with compressed air.

Air/Oil Separator Choked

The separator element removes oil droplets from compressed air. As it loads up with oil and debris, the differential pressure across it rises. When the DP exceeds the setpoint (usually around 10 psi), the controller alarms. Replace the element — do not simply reset and continue.

Low Oil Pressure

Check oil level first. Then check the oil filter — a clogged filter on initial cold startup can drop pressure before oil flow is established. If oil level and filter are fine, inspect the oil pressure sensor and wiring.

Parts Often Needed

PartNotes
Oil separator elementAmazon | Main periodic wear item
Oil filterAmazon | Replace with separator service
Temperature sensorAmazon | Common after heat cycling
Cooling fan contactorAmazon | Check on temp-related faults

Jump to Fix

When to Call a Pro

ELGi has a global dealer network. If faults persist after parts replacement, contact an ELGi authorized service center for airend diagnostics and controller configuration checks.