Skip to content
Industrial Error Code Fixes
Go back

Carrier Furnace Error Codes — Complete Guide

⚡ Quick Answer

Carrier furnace error codes: all flash codes with meanings, causes, and fixes for every Carrier gas furnace.

⚡ AT A GLANCEScroll down for full repair guide
What it meansCarrier furnace error codes: all flash codes with meanings, causes, and fixes for every Carrier gas furnace.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededCarrier flame sensor

Parts to price first

Check the part before you book service.

Carrier flame sensor

Part: Carrier HH18ZA641

The fix for codes 22 and 34 when cleaning the rod does not restore a reliable flame-proving signal.

Carrier limit switch kit

Part: Carrier HH18HA600

For code 13 or 33 limit lockouts once the filter, registers, and blower have been checked.

Carrier pressure switch

Part: Carrier HH18HA719

Replace for code 31 or 32 after the hose, drain trap, and inducer check out.

Carrier draft inducer motor

Part: Carrier 318984-753

For codes 40, 41, and 42 inducer motor faults when RPM feedback or the motor itself fails.

$150-$300Check price

Replacement HVAC air filter (exact size)

Restricted airflow trips high-limit, low-airflow, and frozen-coil faults. Filter King cuts custom sizes if the standard size is out of stock.

Furnace and AC filters in bulk (DiscountFilterStore)

Stock a year of filters so the airflow fault does not come back after the fix.

Nordic Pure MERV 8-13 pleated filters (American-made)

Standard and odd sizes in MERV 8, 11, and 13. Match the MERV your blower is rated for; a filter that is too restrictive trips the same airflow faults as a dirty one.

Furnace parts and sequencers (Mobile Home Parts Store)

Limit switches, sequencers, blower motors, and control boards for Nordyne, Intertherm, Miller, and Coleman furnaces.

Gas furnaces, control boards, and blower parts (HVACDirect)

Wholesale-priced OEM-equivalent parts and full systems shipped direct. Compare before paying contractor markup on a replacement.

Repair intent

Need this fixed instead of diagnosed?

Carrier furnace error codes: all flash codes with meanings, causes, and fixes for every Carrier gas furnace.

Carrier Furnace Error Codes — Quick Reference

Carrier gas furnaces use a blinking LED on the control board to communicate fault codes. Count the flashes in a repeating pattern — the number of blinks identifies the fault. Single-digit codes are common on older IFC boards; newer Carrier Infinity and Performance series use two-digit codes. Pull the furnace door and look through the sight glass or remove the lower access panel to see the LED.

CodeMeaningQuick Fix
11No previous fault storedNormal after power cycle
12Blower on after power up / prior to heatCheck blower wheel; verify prior call
13Limit device lockout (retries exceeded)Check filter, airflow, heat exchanger
14Ignition lockout (retries exceeded)Check gas, igniter, flame sensor
21Gas heating lockoutManual reset; check gas pressure
22Abnormal flame-proving signalClean flame sensor rod
24Secondary voltage fuse openCheck for short in low-voltage wiring
25Model plug missing or incorrectReplace/reseat model plug
31Pressure switch stuck openCheck inducer, hose, pressure switch
32Pressure switch stuck closedCheck pressure switch hose routing
33Limit or flame roll-out switch openCheck filter, ducts, roll-out switch
34Ignition proving failureClean flame sensor; check gas valve
40Inducer high-speed faultInducer motor issue
41Inducer motor faultReplace inducer motor
42Inducer motor fault (secondary)Verify inducer RPM feedback
43Low-voltage control faultCheck transformer and 24V circuit
44Blower motor faultCheck blower motor and capacitor
45Control board faultReplace IFC board
46Check IFCBoard self-diagnosis fault
52Duplicate serial numberIFC/comm setup issue
54Soft lockout — low pressure switch openPressure switch or inducer fault
58Indoor air quality sensor faultCheck IAQ sensor wiring

Technician Tips

Carrier uses different diagnostic systems across furnaces, heat pumps, chillers, mini-splits, VRF equipment, rooftop units, and communicating controls. Confirm the full model number and whether the fault came from the indoor board, outdoor board, thermostat, or equipment controller before matching it to a repair path.

Start with power, wiring, airflow or water-flow, sensor, condensate, and safety-circuit checks before ordering control boards. If the same code returns after one reset and the basic cause is not obvious, test the named circuit instead of repeatedly cycling the equipment.

Common replacement parts for Carrier systems:

Need Replacement Parts?

Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

Most Common Codes

Code 13: Limit Device Lockout

The furnace tried to heat multiple times but the high-limit switch tripped each time. Most often caused by a clogged air filter, closed supply/return registers, or a failing blower motor. Replace the filter first. If that doesn’t solve it, check for blocked ducts and verify the blower wheel spins freely.

Code 14: Ignition Lockout

The furnace failed to establish a flame after the maximum number of ignition attempts. Check that the gas supply valve is open, verify gas pressure (3.5” WC minimum for natural gas), inspect the hot-surface igniter for cracks, and clean the flame sensor rod with fine steel wool or 400-grit sandpaper.

Code 31: Pressure Switch Stuck Open

The inducer motor started but the pressure switch never closed. Most common causes: cracked pressure switch hose, a clogged condensate drain trap (on 90%+ furnaces), weak inducer motor, or a failed pressure switch itself. Start by inspecting the rubber hose between the inducer and the pressure switch.

Code 33: Limit or Roll-Out Switch Open

A safety limit opened during operation. On 80% furnaces this usually means airflow is restricted — check the filter and blower. On 90%+ furnaces, also check the secondary heat exchanger. If the roll-out switch tripped, do not reset it until you find the cause — that switch protects against flue gas spillage.

Code 34: Ignition Proving Failure

The igniter lit the burner but the flame sensor didn’t confirm a flame reliably. Clean the flame sensor rod (the single metal rod that sits in the burner flame). If cleaning doesn’t fix it, check the microamp signal; healthy flame signal is typically 2–8 µA.

Code 45: Control Board Fault

The IFC board has diagnosed itself as faulty. Before replacing, verify all wiring connections are tight, there are no shorted low-voltage wires, and the 3-amp fuse on the board is intact.

When to Call a Pro

If you’ve reset the furnace and the same code returns immediately, or if codes 21 or 33 involve a tripped roll-out switch, contact a licensed HVAC technician — these situations can indicate cracked heat exchangers or flue gas spillage, which are safety hazards.

Quick FAQ

What does code 31 mean on a Carrier furnace?

Code 31 means the pressure switch stuck open: the inducer motor started but the switch never closed. The most common causes are a cracked pressure switch hose, a clogged condensate drain trap on 90%+ furnaces, a weak inducer motor, or a failed pressure switch.

How do I fix Carrier furnace code 33?

Code 33 means a limit or flame roll-out switch opened. On 80% furnaces check the filter and blower for restricted airflow; on 90%+ furnaces also check the secondary heat exchanger. A tripped roll-out switch can indicate a cracked heat exchanger, so call a licensed technician.

What causes Carrier code 14 ignition lockout?

The furnace failed to establish a flame after the maximum number of ignition attempts. Confirm the gas valve is open, verify gas pressure is at least 3.5 inches WC for natural gas, inspect the hot-surface igniter, and clean the flame sensor rod.

Should I replace the board for Carrier code 45?

Not right away. Code 45 means the IFC board diagnosed itself as faulty, but first verify all wiring connections are tight, there are no shorted low-voltage wires, and the 3-amp fuse on the board is intact.


Need a professional? Compare HVAC repair options before replacing parts.
Compare Repair Options
Share this post on:

Previous Post
Carrier AquaSnap Chiller Fault Codes — 30RB/30RQ Guide
Next Post
Carrier Geothermal Error Codes - Low Pressure, Freeze, ECM