York TG9 Furnace Error Codes — Fault Code Diagnostic Guide

⚡ Quick Answer

Complete guide to York TG9 furnace error codes, LED flash sequences, common fault causes, and step-by-step repair procedures for HVAC technicians.

York TG9 Furnace Error Codes — What They Mean

The York TG9 is a 96% AFUE two-stage variable-speed gas furnace. It is part of York’s Affinity series and uses a communicating control board when connected to a York proprietary thermostat, or a standalone LED diagnostic when used with a conventional thermostat. The TG9 uses an ECM blower motor for variable airflow and a two-stage gas valve for comfort-based modulation. It vents via PVC condensing flue and produces condensate requiring a drain trap.

Jump to Fix

York TG9 LED Flash Code Reference

Flash SequenceFault
1 flashNormal — waiting for call
2 flashesPressure switch stuck open
3 flashesPressure switch stuck closed
4 flashesHigh-limit switch open
5 flashesIgnition lockout — 3 failed attempts
6 flashesRollout switch open
7 flashesFlame sensed without gas valve call
8 flashesInducer motor speed fault
9 flashesBlower motor fault
10 flashesControl board fault
11 flashesCommunication fault (if connected to York thermostat)
RapidLow voltage — below 18VAC

Common Causes by Code

Step-by-Step Fix {#fix}

  1. Read the LED — The York TG9 LED is inside the control compartment, visible through the observation window in the lower panel. Count the flash sequence (flashes, then pause, then repeat).
  2. For 2 flashes (pressure switch) — Locate the condensate trap (under the secondary heat exchanger or inside the furnace cabinet). Remove the trap and flush it with water. Reconnect and restart. If the fault clears, the condensate drain was blocked.
  3. For 5 flashes (ignition lockout) — Reset by pressing the board’s reset button or cycling power at the furnace switch. Watch the ignition sequence on restart: inducer → pressure switch closes → igniter heats → gas valve opens. Each step should happen in sequence within 30–60 seconds.
  4. For 8 flashes (inducer speed) — Check the inducer motor tach wire. It is a small-gauge wire (often white or yellow) connected to a 3-pin connector on the inducer motor. Verify the connector is fully seated.
  5. For 9 flashes (blower) — Verify the ECM motor is getting 120VAC at the motor power connector. Check the communication cable (5-pin) between the motor module and the board. If the motor runs but slowly, the motor module may need replacement.

Parts Often Needed

PartNotes
Hot surface igniterAmazon | Silicon nitride; specific to TG9 model
Flame sensorAmazon | Rod-type; clean before replacing
Condensate trapAmazon | PVC trap assembly; critical to pressure switch operation
ECM blower motor moduleAmazon | Module only — verify motor spins freely before replacing
Inducer motor assemblyAmazon | ECM type; includes tach feedback
Pressure switchAmazon | Check tubing and condensate trap first

When to Call a Pro

The York TG9 ECM motor and variable-speed control logic require familiarity with York’s communicating control system. If the TG9 is installed with a York proprietary thermostat and showing thermostat-level fault codes, a York dealer with system diagnostic tools is needed for full root-cause analysis. Rollout switch trips (Code 6) must be investigated for heat exchanger integrity before returning to service.


🔧 Need a professional? Get free quotes from certified HVAC contractors near you.