York Furnace 6 Flashes Error Code — Pressure Switch Fault Fix

⚡ Quick Answer

York furnace 6 flashes error code indicates an inducer pressure switch fault — here's how to diagnose and fix it on York, Coleman, and Luxaire furnaces.

⚡ AT A GLANCEScroll down for full repair guide
What it meansYork furnace 6 flashes error code indicates an inducer pressure switch fault — here's how to diagnose and fix it on York, Coleman, and Luxaire furnaces.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
Repair time10-45 minutes for basic checks
Repair intent

Need this fixed instead of diagnosed?

York furnace 6 flashes error code indicates an inducer pressure switch fault — here's how to diagnose and fix it on York, Coleman, and Luxaire furnaces.

Error Code: York Furnace 6 Flashes

What it means: Six LED flashes on a York, Coleman, or Luxaire furnace indicate an inducer pressure switch fault. The control board energized the draft inducer motor, waited for the pressure switch to close (confirming adequate negative pressure in the heat exchanger), and the switch never closed — or it closed and reopened during operation. After timing out, the board locks out and repeats the 6-flash sequence.

York, Coleman, and Luxaire are all manufactured by Johnson Controls and share the same control platform, so this diagnostic applies to all three brands.

Common Causes

Step-by-Step Fix {#step-by-step-fix}

  1. Power down the furnace. Set the thermostat to OFF and turn off the furnace disconnect switch. Wait 60 seconds before opening the cabinet.

  2. Locate the pressure switch. On most York 80% units, there is one pressure switch mounted near the inducer assembly. On 90%+ (condensing) units, there are typically two switches — one for the inducer and one for the secondary heat exchanger. The 6-flash code typically points to the primary inducer switch.

  3. Inspect the pressure switch hose. Trace the small diameter rubber tubing from the inducer housing port to the switch fitting. Look for kinks, cracks, or disconnected ends. Blow gently through the hose to confirm it’s clear. Replace with matching ID silicone tubing if cracked.

  4. Check for water in the hose. On a 90%+ unit, tip the hose downward — water may drain out. If water is present, the condensate drain is blocked. Clear the drain trap and drain line (usually a 3/4” PVC line running to a floor drain or condensate pump). On York units, the drain trap is often serviceable by removing a single screw cap.

  5. Test the pressure switch with a multimeter. Set to continuity or resistance. With the furnace off and hose disconnected, the switch should read OPEN (no continuity). Gently apply suction to the switch port with a hand vacuum pump or by mouth — the switch should click closed (continuity) at the rated trip point (typically –0.50 to –1.20” W.C. depending on model). If it won’t close or stays closed, the switch is failed.

  6. Inspect the inducer motor. Restore power temporarily and watch the inducer spin up. Listen for grinding, squealing, or sluggish startup. Measure amperage with a clamp meter — compare to the motor nameplate. An inducer running hot or drawing over nameplate amps is failing.

  7. Check the flue pipe. Walk outside and visually inspect the PVC termination. Look for blockages, ice buildup, or debris. On two-pipe systems, verify both the intake and exhaust pipes are clear.

  8. Replace the pressure switch if faulty. The OEM York replacement for most mid-range units is part 025-27766-000 (~$35). Always verify the part number against the wiring diagram inside your furnace’s cabinet door — York uses multiple switch ratings across its product line.

Parts That May Need Replacement {#parts-that-may-need-replacement}

PartPart NumberTypical CostWhere to Buy
York Pressure Switch (primary)025-27766-000$30–$45Repair Clinic /
Inducer Draft Motor (if failed)S1-32435820000$180–$280Repair Clinic / HVAC distributor
Pressure Switch Tubing (bulk)Generic 3/16” ID silicone$5–$10Amazon / hardware store
Condensate Drain TrapS1-37327820000$18–$30Repair Clinic

Technician Tips

Modern furnaces use LED flash codes on the control board to diagnose failures. Before calling for service, count the number of flashes between pauses and check your owner’s manual for the code chart. The most common furnace error — 1-4 flashes usually means ignition failure — is often caused by a dirty flame sensor. The flame sensor is a $15-30 part that takes 10 minutes to clean. Remove it with a 1/4” nut driver, gently scrub the metal rod with emery cloth or a dollar bill (yes, a dollar bill — it’s the right abrasiveness), and reinstall. This fixes about 60% of “no heat” service calls.

DIY vs Pro: Error codes related to pressure switches (usually 2-3 flashes) often indicate blocked vents or condensate drains — safe to check yourself. Codes related to gas valves or ignition modules (4+ flashes) are best left to a licensed HVAC technician.

Need Replacement Parts?

Finding the right replacement parts for your equipment is critical to getting it running again. Check current prices on Amazon — prices and availability change frequently.

When to Call a Professional

If the flue or intake is blocked with ice, do not attempt to run the furnace. On cold days, ice can reblock a cleared line within hours — the root cause is usually flue pipe that runs too horizontally, is too close to the ground, or has inadequate slope. Correcting the flue routing requires a licensed HVAC contractor. Similarly, if the inducer motor has failed, replacement on a York 90%+ unit involves removing the secondary heat exchanger in some configurations — a job that requires experience to avoid damaging the plastic heat exchanger. A cracked or failed secondary heat exchanger is a carbon monoxide risk and must be confirmed clear before returning the unit to service.

Pro tip: York furnaces with a 6-flash fault that clears on its own during warm weather and returns every winter almost always have a condensate freeze problem. The fix is adding freeze protection to the condensate line or rerouting it away from exterior walls — not replacing parts.


Need a professional? Compare certified HVAC repair options before replacing parts.