Skip to content
Industrial Error Code Fixes
Go back

Weil-McLain E04 Error Code — Causes & Fix

⚡ Quick Answer

What Weil-McLain E04 error code means, why the sensor faults, and how to fix it step by step.

Weil-McLain E04 Error Code — What It Means

Weil-McLain E04 indicates a temperature sensor fault — one of the boiler’s thermistors (supply, return, or DHW sensor depending on the model) is reading outside its valid range. On Weil-McLain ultra and gas-fired condensing boilers, the control monitors multiple temperature points; an open or shorted sensor on any one of them triggers E04 and shuts down the boiler to prevent uncontrolled operation. The specific sensor that failed can often be identified by consulting the boiler’s display history or service menu.

Jump to Fix

Common Causes

Step-by-Step Fix {#fix}

  1. Read the fault history — Access the boiler’s diagnostics menu (consult your model’s installation manual). Identify which sensor is flagged: supply (S1), return (S2), or DHW (S3). This narrows your search immediately.
  2. Inspect the sensor immersion well — The thermistor probe inserts into a brass or stainless well in the water-side piping. Confirm the probe is fully seated and the mounting nut is tight. A partially withdrawn probe reads air temp.
  3. Check the connector — Disconnect the sensor connector at the boiler control. Inspect for corrosion, pushed-out pins, or moisture. Clean with contact cleaner.
  4. Measure thermistor resistance — Disconnect the sensor and measure resistance at room temperature (~70°F/21°C). Weil-McLain thermistors typically read ~10 kΩ at 77°F (25°C). Consult your model’s table for exact specs. Out-of-range = replace.
  5. Replace the thermistor — Drain the relevant section of piping (or the boiler if required), remove the immersion well thermistor, install the new sensor, and tighten to the specified torque.
  6. Reset and verify — Power cycle the boiler (off for 30 seconds) and fire it through a complete heating cycle. Confirm E04 is cleared and supply/return temps display correctly on the control.

Parts Often Needed

PartNotes
Supply thermistor (S1)Amazon | Weil-McLain model-specific; verify for Ultra vs. Gold/CGa series
Return thermistor (S2)Amazon | Match immersion well length and resistance spec
DHW sensor (S3)Amazon | Only on combi models with domestic hot water capability

When to Call a Pro

If sensor replacement doesn’t clear E04, the boiler control board may have a failed input. Weil-McLain control board replacement on condensing boilers requires proper setup and parameter configuration — have a licensed heating contractor handle board replacement to ensure the boiler is commissioned correctly.


🔧 Need a professional? Get free quotes from certified HVAC contractors near you.
Get Free Quotes →
Share this post on:

Previous Post
True Refrigeration E3 Error Code — Causes & Fix
Next Post
Yaskawa VFD Fault BB — Causes & Fix