Vertiv (Liebert) UPS Fault Codes - Complete Guide

⚡ Quick Answer

Vertiv Liebert UPS fault codes for GXT, EXS, APM, and 3-phase systems: alarms, causes, and repair guidance.

Vertiv (Liebert) UPS Fault Codes - Quick Reference

Vertiv (formerly Liebert, now Vertiv brand) UPS systems include GXT4/5, EXS, APS, APM, NXL, and Trinergy lines. Faults display on the local LCD and are logged via Vertiv Environet or Liebert IntelliSlot network cards.

FaultSystemMeaningQuick Fix
Battery FaultAllBattery string failureReplace battery module
OverloadAllLoad exceeds UPS capacityReduce load
On BatteryAllUtility power lossCheck input
Replace BatteryGXT/APSBattery end of lifeReplace battery
Static BypassAllUPS transferred to bypassCheck for internal fault
Fan FailureAPM/NXLCooling fan failedReplace fan module
OvertemperatureAllThermal limit exceededCheck cooling
Rectifier FaultNXL/APMRectifier failureContact service
Inverter FaultAllInverter failureTransfer to bypass, contact service
Communication FaultAllNetwork card offlineCheck IntelliSlot card

Most Common Faults

Battery Fault

Vertiv Liebert GXT and EXS systems monitor battery voltage and impedance. A battery fault on GXT4/5 means one or more batteries in the internal string have failed. Replace the complete battery set - Vertiv recommends replacing all batteries at once, not individual cells. Use Vertiv-approved replacement batteries for warranty compliance.

Overtemperature

Vertiv UPS systems require adequate airflow. GXT rack-mount units need 1U of clearance above and below. APM and NXL systems have dedicated cooling sections - check that front air intakes are clear and rear exhausts are not blocked by adjacent equipment.

Inverter Fault

An inverter fault on a Vertiv system causes automatic transfer to static bypass. The load remains powered but unprotected. Contact Vertiv service - inverter module replacement on APM and NXL systems is a field-replaceable procedure but requires factory-trained personnel.

Fan Failure

Vertiv APM and NXL modular systems have hot-swappable fan modules. Check the Vertiv part number on the fan tray label. Fan failures in these systems generate a critical alarm and should be addressed immediately - insufficient cooling leads to rapid component degradation.

Parts Often Needed

PartNotes
Battery module (GXT/EXS)Amazon | Replace complete set
Fan module (APM/NXL)Amazon | Hot-swappable
IntelliSlot network cardAmazon | Replace on communication fault
Bypass module (APM)Amazon | Replace on bypass fault
Rectifier moduleAmazon | Factory service or replacement

When to Call a Pro

Vertiv APM, NXL, and Trinergy three-phase systems require Vertiv-authorized service for inverter, rectifier, and capacitor maintenance. Annual preventive maintenance by a Vertiv service partner is recommended for critical infrastructure installations.