Siemens Micromaster F0060 - Causes & Fix

3 min read

Independent. We don't sell parts, so we tell you when not to buy one.

⚡ Quick Answer

F0060 means ASIC timeout, an internal drive electronics failure. Most likely fix: reset the drive. If it returns, replace the inverter.

Difficulty Advanced
Est. time 1-3 hrs
Tools Multimeter , service manual, ESD strap

Siemens Micromaster F0060 — What It Means

F0060 on a Siemens Micromaster drive stands for ASIC Timeout. This fault indicates that the drive’s internal application-specific integrated circuit (ASIC) did not complete its processing or communication task in the expected time window. It is an internal electronics failure in the drive’s control section, not a motor overload, wiring fault, or external device problem. Siemens documentation confirms this code points to a failure within the inverter’s control electronics.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Record the fault and operating conditions (load, temperature, runtime) in your maintenance log before taking any action.
  2. Reset the drive using one of three methods: cycle the control power off and back on, use the keypad reset function, or send a digital reset command if your control system supports it.
  3. Monitor for recurrence by running the drive under normal load for at least one full duty cycle to see if F0060 reappears.
  4. Inspect the enclosure and ventilation to confirm the drive is not overheating and that intake and exhaust vents are clear of dust and obstructions.
  5. Check supply power quality at the input terminals with a multimeter or power-quality meter to rule out voltage sags, surges, or high line noise that might stress the control board.
  6. Verify all control wiring and terminal connections for tightness, corrosion, or signs of arcing, even though this fault is internal, to eliminate any contributing external factors.
  7. Replace the inverter if the fault returns after reset and environmental checks are normal, as Siemens service documentation specifies inverter replacement as the corrective action for persistent F0060 faults.

Parts Often Needed

PartNotes
Siemens Micromaster inverter/converter assemblyAmazon | Match the exact model, frame size, and voltage rating to your original drive. Siemens specifies inverter replacement for persistent F0060.
Replacement control board (if available separately)Amazon | Some Micromaster models offer field-replaceable control boards. Verify availability and compatibility with Siemens or an authorized distributor.

When to Call a Pro

Call a qualified drives technician or contact Siemens service if the F0060 fault returns after a simple reset, if you lack experience working inside variable-frequency drives, or if your process cannot tolerate downtime for trial-and-error troubleshooting. Persistent ASIC timeout faults require inverter replacement or board-level repair that is best handled by factory-trained personnel with access to Siemens diagnostic tools and genuine replacement parts. If the drive is under warranty or part of a critical industrial process, involve your Siemens representative or a certified integrator immediately to avoid voiding coverage or risking further equipment damage.


🔧 Need a professional? Get free quotes from certified HVAC contractors near you.
Get Free Quotes →
Share this post on:

Previous Post
Siemens Micromaster F0071 - Causes & Fix
Next Post
Siemens Micromaster F0054 - Causes & Fix