Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Rheem RA13 guide for high-pressure, low-pressure, compressor overload, control-board, thermistor, anti-short-cycle, and low-voltage faults.
Rheem RA13 guide for high-pressure, low-pressure, compressor overload, control-board, thermistor, anti-short-cycle, and low-voltage faults.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
The Rheem RA13 (and its Ruud counterpart, the RA13) is a 13–14 SEER single-stage central air conditioner using R-410A refrigerant. It is designed for replacement and new construction applications where budget is the primary constraint. The RA13 uses a conventional control board with a status LED to communicate faults via flash codes. These units do not have a communicating bus — they operate in a standard thermostat-controlled on/off mode.
| Flash Sequence | Fault |
|---|---|
| 1 flash | Normal — standby |
| 2 flashes | High-pressure switch open |
| 3 flashes | Low-pressure switch open |
| 4 flashes | Compressor protection device open |
| 5 flashes | Control board fault |
| 6 flashes | Thermistor fault — outdoor sensor |
| 7 flashes | Anti-short cycle lockout (5-minute delay) |
| Rapid continuous | Low voltage — below 18VAC |
| Part | Notes |
|---|---|
| Dual run capacitor | Most common RA13 failure; affects both fan and compressor |
| Contactor | 2-pole; inspect for pitting and carbon buildup |
| High-pressure switch | Spade terminals; replaces easily |
| Low-pressure switch | 50 PSIG cutout for R-410A |
| Control board | Check fuse first before ordering board |
| Condenser fan motor | Match RPM, HP, and shaft size |
Heat-pump, rooftop, and air-conditioner faults usually come from airflow, condensate drainage, outdoor coil condition, defrost sensors, pressure switches, capacitors/contactors, or low-voltage communication. Check filters, coils, drains, disconnect power, and thermostat wiring before assuming the compressor or board has failed.
DIY vs Pro: Filter, coil, drain, and visual wiring checks are reasonable owner tasks. Refrigerant diagnostics, capacitor testing, contactor replacement, and compressor or control-board work should be done by an HVAC technician.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Refrigerant handling on the RA13 requires EPA 608 certification. If the compressor draws high amperage (above nameplate FLA) but produces no cooling, the compressor may be mechanically failed — a technician with a clamp-on ammeter and manifold gauges can confirm this before an expensive replacement decision is made.