Skip to content
Industrial Error Code Fixes
Go back

Lennox iComfort EFO Error Code — Excessive Flame Out and Common iComfort Faults

⚡ Quick Answer

Lennox iComfort EFO (Excessive Flame Out) error code explained — causes, step-by-step diagnosis, and fixes for EFO and other common iComfort alert codes.

Lennox iComfort EFO Error Code — What It Means

The EFO (Excessive Flame Out) alert on a Lennox iComfort S30 or M30 communicating thermostat means the furnace burner lit successfully but lost flame unexpectedly — and this has happened multiple times in a short window. The iComfort system tracks how many times the burner lights and then goes out abnormally. When that count exceeds the threshold (typically 5 flame-out events within a set period), the system escalates from a routine lockout to an EFO alert and shuts down for safety.

EFO is distinct from a simple ignition failure (where the burner never lights). With EFO, the burner does light — but something is snuffing it out before the call for heat is satisfied. That intermittent nature is what makes EFO harder to diagnose than a hard no-light condition.

Jump to Fix

Common Causes

Step-by-Step Diagnosis {#fix}

  1. Read the iComfort alert history — On the S30 or M30, go to Menu > Settings > Advanced Settings > Alerts. Look for the pattern: how many EFO events have occurred, and at what time of day. EFO that always occurs after 10–15 minutes of runtime points toward the heat exchanger or vent. EFO that occurs immediately on every ignition attempt points toward the flame sensor or gas pressure.

  2. Clean the flame sensor first — This resolves EFO in the majority of cases. Shut off power at the disconnect. Remove the furnace access panel and locate the flame sensor — a single metal rod with a ceramic insulator, positioned in the burner flame path. Remove the one screw holding it, slide it out, and lightly polish the metal rod with fine steel wool or a dollar bill (a non-abrasive option). Do not sand aggressively — you want to remove contamination, not metal. Reinstall and test.

  3. Check gas manifold pressure — A qualified tech should connect a manometer to the gas valve’s manifold pressure port. For natural gas, the typical manifold pressure is 3.5 inches WC; for propane, 10 inches WC. Pressures outside these ranges cause unstable combustion and EFO.

  4. Inspect the vent termination — Go outside and check the PVC exhaust termination. Clear any obstructions. On cold days, ice can form on the termination cap. Also check that the air intake termination isn’t drawing in exhaust gases (short-cycling the combustion air).

  5. Test the draft inducer — With the furnace running, listen to the inducer motor for changes in pitch or speed during the operating cycle. A motor with a failing bearing will often slow down as it warms up, changing the combustion air volume mid-cycle.

  6. Inspect the heat exchanger — If EFO occurs 10–20 minutes into a cycle after supply air temperature builds up, suspect the heat exchanger. A cracked exchanger is confirmed with a combustion analyzer, a dollar bill test at supply registers (looking for flutter when the blower turns on), or a qualified inspection with a camera scope.

  7. Reset the alert and monitor — After cleaning the flame sensor, reset the iComfort (Settings > Advanced Settings > Reset > Equipment Reset). Run a complete heating cycle and watch the heat status screen for flame-out events.

Other Common Lennox iComfort Error Codes

CodeMeaningQuick Fix
Alert 225Outdoor unit communication lossCheck low-voltage wiring between air handler and outdoor unit
Alert 31Indoor unit communication faultVerify thermostat wiring at air handler terminal block
EFOExcessive Flame OutClean flame sensor; check gas pressure and vent
High LimitHeat exchanger over-temperatureReplace air filter; check blower operation
Low PressureRefrigerant low pressure faultRefrigerant charge check by licensed tech

Parts You May Need

PartNotes
Replacement flame sensorAmazon — Verify part number on the label; common Lennox sensors are 38L73, 10L56
Draft inducer capacitorAmazon — A failed run capacitor causes the inducer to run slow
Draft inducer motorAmazon — Replace when bearings are noisy or motor won’t reach full speed
iComfort S30 thermostatAmazon — Replace if the thermostat itself is generating false alerts

When to Call a Technician

If cleaning the flame sensor doesn’t resolve EFO within 1–2 heating cycles, call a Lennox-certified HVAC technician. Gas pressure measurement requires a manometer and knowledge of the gas train components. A cracked heat exchanger is a carbon monoxide hazard and must be inspected — and the furnace taken out of service — by a licensed professional. Do not continue operating a furnace with confirmed EFO that doesn’t respond to the flame sensor cleaning step.


🔧 Need a professional? Get free quotes from certified HVAC contractors near you.
Get Free Quotes →
Share this post on:

Previous Post
Haas Alarm 120-129 — Automatic Tool Changer (ATC) Fault Fix Guide
Next Post
Lochinvar Boiler F08 Flame Failure Error — Causes and Fix