Lennox Furnace Blink Codes — Complete Red Light Guide

⚡ Quick Answer

Complete Lennox furnace blink code reference covering Elite, Merit, Signature, G60, G61, and SLP98 series. Find your model prefix and read the LED codes step by step.

⚡ AT A GLANCEScroll down for full repair guide
What it meansComplete Lennox furnace blink code reference covering Elite, Merit, Signature, G60, G61, and SLP98 series. Find your model prefix and read the LED codes step by step.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
Repair time10-45 minutes for basic checks
Repair intent

Need this fixed instead of diagnosed?

Complete Lennox furnace blink code reference covering Elite, Merit, Signature, G60, G61, and SLP98 series. Find your model prefix and read the LED codes step by step.

Lennox furnaces signal errors with a diagnostic LED on the control board. The pattern depends on your model series. Most Lennox furnaces use a green or amber LED that blinks a number of times, pauses, then repeats. A slow steady blink (once every few seconds) means the furnace is standing by with no faults. A counted sequence of 1-10 rapid blinks is an error code.

Some newer Lennox models use a seven-segment display that shows numeric codes instead of blinks. The SLP98 series also displays diagnostic codes on the iComfort thermostat screen.

Identify Your Lennox Series

Lennox makes several furnace series with slightly different code mappings. Find your model number on the rating plate inside the access panel. The model prefix tells you which series you own.

SeriesModel PrefixCode Type
EliteEL195, EL180, EL2961-10 blink codes
MeritML195, ML180, ML2961-10 blink codes
SignatureSL280, SL2971-10 blink codes + seven-segment
G60 / G61G60, G61Amber/green LED flashes
G71G71Seven-segment display
SLP98SLP98iComfort thermostat codes
ML193ML1931-10 blink codes

Elite, Merit, Signature, and ML193 Series

BlinksMeaningWhat to Check
1Ignition failure (no flame after 3 attempts)Flame sensor, gas valve, spark igniter
2Gas valve relay faultWiring to gas valve, control board
3Pressure switch failureCondensate drain, tubing, inducer motor, vent
4Open limit switchAir filter, registers, blower, heat exchanger
5Flame sensed with gas valve offStuck gas valve, control board short
6Lost flame sense during runDirty flame sensor, weak microamp signal
7Gas valve circuit faultWiring, valve resistance, board
8Blower motor faultCapacitor, motor bearings, ECM module
9Pressure switch timingBlocked vent, long vent runs, inducer weak
10Watchdog / internal faultControl board replacement

G60 and G61 Series

The G60 and G61 use a dual-color LED. Amber and green flash in combinations to signal faults.

Flash PatternMeaning
Slow green (steady)Standby, no faults
1 amber flashIgnition failure
2 amber flashesPressure switch failure
3 amber flashesLimit switch open
4 amber flashesFlame sensor failure
5 amber flashesGas valve error
Fast green flashLow line voltage
Rapid alternating amber/greenControl board failure

SLP98 Series (iComfort Thermostat Codes)

The SLP98 communicates error codes through the thermostat. Common codes include:

CodeMeaning
100No communication with furnace
125IGV (Infinities Gas Valve) failure
200Blower motor fault
300Flame sensor weak signal
414Rollout switch open
500Pressure switch circuit open

Most Common Lennox Codes in the Field

This is the most common Lennox error across all series. The furnace lights, runs for a few seconds or minutes, then the flame goes out and the board detects no flame signal. The furnace tries to relight three times then locks out.

The cause is almost always a dirty flame sensor. The flame sensor is a silicon carbide rod mounted in the burner flame. Over time, a coating of combustion byproducts insulates the rod and reduces the microamp signal the control board needs to see (typically 2-6 microamps DC). Cleaning the rod with a fine abrasive restores the signal.

Turn off power to the furnace. Remove the flame sensor (one screw, slide it out). Gently clean the rod with fine emery cloth or a dollar bill. Do not use sandpaper that is too aggressive. Reinstall the sensor and restore power. This fixes roughly 70% of 6-blink calls.

Three blinks on Lennox means the pressure switch failed to close when the inducer started, or failed to open when the inducer stopped. Start with the condensate drain. High-efficiency Lennox furnaces produce water. If the drain is blocked, water backs up and blocks the pressure switch hose. Check the drain tee for standing water. Clear it with a wet/dry vacuum.

Next, inspect the pressure switch hose. It runs from the switch to the inducer housing. Look for cracks near the barb fittings. Replace cracked hose.

Four blinks mean the high limit switch opened. This is an airflow problem 90% of the time. Check the air filter first. Then check all supply registers to make sure they are open. A blower motor running slow because of a bad capacitor or failing bearings can also trigger this code.

414 (Rollout Switch Open, SLP98 and Some Elite Models)

Code 414 means a rollout switch has tripped. This is a safety-critical fault. The rollout switch detects flame coming out of the burner tube instead of staying inside the heat exchanger. Do not reset this without understanding why it tripped.

If you can see the small button on the rollout switch, you can press it back in (manual reset). But if the switch trips again within the same heat cycle, you have a serious problem: blocked heat exchanger, improper gas pressure, or blocked flue. Call a technician.

Diagnostic Workflow

Step 1: Read and Record the Code

Open the blower compartment. Find the diagnostic LED on the control board. Watch the code through three full sequences to confirm the blink count. Write down the number.

Step 2: Power Cycle

Turn the thermostat to OFF. Flip the furnace breaker to OFF. Wait 30 seconds. Restore power and set the thermostat to call for heat. Watch the sequence. If the same code returns, proceed to diagnosis.

Step 3: Follow the Code

Use the code table above to identify the problem area. Start with the cheapest and most common fix for that code. For 1 blink, clean the flame sensor. For 3 blinks, check the condensate drain and pressure switch tubing. For 4 blinks, change the filter.

Step 4: Clear the Code

Lennox control boards have a diagnostic button on some models. Press and hold the button for 5 seconds to clear a soft lockout on Elite and Merit series. If your board does not have a diagnostic button, power cycling at the breaker clears all codes.

Lennox Diagnostic Button Reset

Some Lennox Elite and Merit furnaces have a small black button on the control board labeled DIAGNOSTIC or SERVICE. Press and hold this button for 5 seconds to reset the control board and clear error codes. This bypasses the power cycle for soft lockouts. If the code returns immediately after pressing the button, the fault is still present.

Parts Reference

PartTypical CostNotes
Flame sensor (Lennox OEM)$20-$45Clean first before replacing
Pressure switch (Lennox OEM)$25-$60Match setpoint to existing part
Limit switch (Lennox OEM)$15-$40Varies by model and opening temp
Rollout switch (manual reset)$15-$35Small red reset button
Condensate drain trap kit$15-$30Common replacement on 90% models
ECM blower motor module$200-$500Lennox OEM recommended

When To Call a Professional

Call a technician if the code returns after you have checked the obvious causes: filter is clean, condensate drain is clear, pressure switch tubing is intact. Codes that come back immediately usually point to component failures that require multimeter testing.

Code 414 (rollout switch) should always be treated seriously. If it trips more than once, do not reset it again without a professional diagnosis. A cracked heat exchanger or blocked flue can allow carbon monoxide to enter your home.

If you smell gas at any point, leave the building immediately and call your gas utility from outside.