Daikin Applied Chiller Fault Codes Guide — WMC / AGZ / ALZ Series

⚡ Quick Answer

Daikin Applied chiller fault codes for WMC, AGZ, ALZ, and centrifugal chillers: alarm descriptions, causes, and troubleshooting steps.

Daikin Applied Chiller Fault Codes — Quick Reference

Daikin Applied chillers (WMC water-cooled scroll, AGZ air-cooled, ALZ air-cooled scroll, and centrifugal units) use the MicroTech III or MicroTech 4 controller to display alarms and shutdowns.

Fault CodeMeaningQuick Fix
Low Pressure CutoutSuction pressure too lowCheck refrigerant charge and evaporator flow
High Pressure CutoutDischarge pressure too highCheck condenser flow/fan and refrigerant
Low Evaporator LWTLeaving water temp too lowCheck flow rate and load
High Motor TempCompressor motor temperature highCheck voltage, load, and cooling
Freeze ProtectionEvaporator temperature near freezeCheck flow, setpoints, and antifreeze
Comm FaultController communication lossCheck BACnet/Modbus wiring
Compressor FaultCompressor protection trippedCheck motor protection and contactor
Low RefrigerantRefrigerant pressure low on both sidesInspect for leaks, check charge

Most Common Faults

Low Pressure Cutout

Low suction pressure is the most frequent chiller alarm. On water-cooled units, check the chilled water flow rate through the evaporator — low flow causes the refrigerant to get too cold. Also check refrigerant charge. On air-cooled units, verify ambient temperature is within the unit’s operating range.

High Pressure Cutout

Discharge pressure is too high. On air-cooled chillers, check: condenser coil cleanliness, fan operation (all fans running), and ambient temperature. On water-cooled units, check condenser water flow rate and entering condenser water temperature.

Freeze Protection

The evaporator approach temperature has reached the freeze protection threshold. Check for: low chilled water flow (pump failure, valve closed), low load causing low flow, or incorrect setpoints. Do not defeat freeze protection — a frozen evaporator is a major repair.

MicroTech III Navigation

  1. HOME → ALARMS to view active alarms
  2. ALARM HISTORY to view past events with timestamp and conditions
  3. SETPOINTS to verify operating limits
  4. UNIT STATUS to view live sensor readings

Parts Often Needed

PartNotes
Refrigerant chargeAmazon | Common after leaks
Condenser fan motorAmazon | Replace on high pressure faults
Flow switchAmazon | Inspect on low pressure and freeze faults
Pressure transducerAmazon | Check on unexplained pressure readings

Jump to Fix

When to Call a Pro

Daikin Applied service providers handle refrigerant work, compressor replacement, and control system configuration. Contact Daikin Applied service at 1-877-554-4834.