Carrier 13 Error Code — Limit Switch Lockout Fix

Verified by Certified Technician
Jump to Fix View Parts

Error Code: Carrier 13

What it means: Code 1-3 is a limit switch lockout. The high-temperature limit switch inside the heat exchanger section tripped because the furnace sensed temperatures above the safe operating threshold (typically 200°F on the primary limit). This is a thermal safety device — when it trips, the gas valve closes but the blower continues running to cool the heat exchanger down. If the limit trips repeatedly, the board locks out with code 13.

The limit switch is doing exactly what it’s designed to do. The fault is almost never the switch itself — it’s whatever is causing the furnace to overheat.

Common Causes

Step-by-Step Fix

  1. Check and replace the air filter immediately. Pull the filter, hold it to light — if you can’t see light through it, it’s too dirty. Replace it now with the correct size and MERV rating (MERV 8–11 is ideal for most residential systems; MERV 13+ can restrict airflow on older furnaces).

  2. Inspect and open all supply and return registers. Walk the home and confirm every register is open. Check for furniture blocking returns. The rule of thumb: never close more than 20% of supply registers on a forced-air system.

  3. Check blower wheel and motor operation. Remove the blower access panel (bottom of the furnace). Inspect the blower wheel for dust buildup — a caked blower wheel can reduce airflow by 30–40%. Clean with a brush and vacuum. Check that the blower runs at full speed during operation; a humming motor that doesn’t spin suggests a failed run capacitor.

  4. Test the run capacitor. With power OFF, discharge the capacitor (short its terminals through a 20K resistor), remove it, and test with a capacitor meter. The µF reading should be within 5–10% of the value printed on the capacitor label. Outside that range = replace.

  5. Inspect the flue pipe for obstructions. Trace the flue pipe from the furnace to the exterior and look for blockages, disconnected joints, or debris. A blocked flue prevents combustion gases from drafting and causes heat to back up into the heat exchanger.

  6. Manually reset the limit switch if needed. Many Carrier limit switches are auto-reset — they reset when the exchanger cools down. Some older or supplemental limit switches have a manual reset button (small red or white button on the switch body). Press it firmly. If the limit requires manual reset every heat cycle, the underlying cause has not been fixed.

  7. Check the heat exchanger for cracks. With the furnace off and cooled, insert a combustion analyzer probe into each heat exchanger cell and look for CO readings while the blower is running. Alternatively, watch for flame rollout or visible flame distortion through the sight glass during ignition. A cracked exchanger requires full replacement — do not continue operating.

  8. Verify return air temperature. Clip a thermometer to the return air plenum. Temperature should be 55–75°F during steady-state operation. Above 80°F return air (common in homes with returns too close to the furnace) indicates system-level airflow problems.

Parts That May Need Replacement

PartWhere to BuyTypical Cost
High-limit switch (Carrier #HH12ZB195 or equiv.)Carrier dealer, Johnstone Supply$15–$40
Blower motor run capacitor (match µF and voltage)HVAC Supply, Amazon$10–$30
ECM blower motor (Carrier OEM #HC43AE116)Carrier dealer, RepairClinic$200–$500
Air filter (16x25x1, MERV 8)Home Depot, Costco$8–$25

When to Call a Professional

If you’ve replaced the filter, opened all registers, confirmed the blower runs at full speed, and the furnace still trips code 13 within one or two heat cycles — stop running the furnace and call a tech. At this point the most likely culprit is a cracked heat exchanger, which is a carbon monoxide hazard. Tell the tech: “Code 13 limit lockout, filter is new, blower runs fine, still tripping. I need a combustion analysis and heat exchanger inspection.”

Pro tip: A limit switch that trips in the first 5 minutes of a heat cycle (not the end) almost always points to a blower problem — the heat exchanger overheats before the blower gets it up to speed. A limit that trips after 20–30 minutes of continuous running usually points to airflow restriction (dirty filter, blocked registers). The timing tells you which direction to dig.