Bryant furnace 31 means the pressure switch did not close. Check condensate, vent pipes, pressure hoses, inducer speed, and switch rating.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Restricted airflow trips high-limit, low-airflow, and frozen-coil faults. Filter King cuts custom sizes if the standard size is out of stock.
Stock a year of filters so the airflow fault does not come back after the fix.
Standard and odd sizes in MERV 8, 11, and 13. Match the MERV your blower is rated for; a filter that is too restrictive trips the same airflow faults as a dirty one.
Limit switches, sequencers, blower motors, and control boards for Nordyne, Intertherm, Miller, and Coleman furnaces.
Wholesale-priced OEM-equivalent parts and full systems shipped direct. Compare before paying contractor markup on a replacement.
Bryant furnace 31 means the pressure switch did not close. Check condensate, vent pipes, pressure hoses, inducer speed, and switch rating.
Bryant furnaces share engineering with Carrier (both are UTC/Carrier brands), so error code 31 carries the same meaning across both: the pressure switch failed to close — or opened unexpectedly — during the inducer startup sequence. The control board starts the inducer draft motor, waits for the pressure switch to confirm adequate negative pressure, and proceeds to ignition. If the switch doesn’t close within the trial window, the board halts, logs fault 31, and blinks the status LED 31 times. This is a safety interlock to ensure combustion gases are being properly vented before gas is introduced.
| Part | Notes |
|---|---|
| Pressure switch | Match the setpoint — Bryant uses both single and dual switches depending on model |
| Inducer draft motor capacitor | Test before replacing the motor — most motor failures are actually capacitor failures |
| Inducer draft motor assembly | Replace if motor is noisy, slow, or seized with a good capacitor |
| Condensate trap | Replace if cracked or if the internal float is stuck |
| Pressure switch tubing | Available by the foot at HVAC supply houses |
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
A persistent 31 after replacing the pressure switch and confirming inducer speed may indicate a cracked heat exchanger, which creates secondary pressure imbalances in the inducer path. A cracked heat exchanger is a serious safety concern — have a licensed HVAC technician perform a combustion analysis before returning the furnace to service.