A.O. Smith EEU6-50H45DV Water Heater Problems & Error Codes

3 min read
⚡ Quick Answer

Tripped high-limit cutoff causes most no-heat calls on this 50-gallon electric model. Press the red reset button on the upper thermostat.

Difficulty Pro recommended
Est. time 1-3 hrs

A.O. Smith EEU6-50H45DV Water Heater Problems & Error Codes — Overview

The EEU6-50H45DV is a 50-gallon residential electric water heater from A.O. Smith running on 240V with two 4,500-watt copper heating elements and an electronic control with standard and vacation modes. This model does not have a published error code table in readily available documentation, so if you see a fault code on the display, scan the QR code on the rating plate to pull the exact manual for your serial number. Most service calls on electric tanks like this one trace back to tripped limits, failed thermostats, open elements, or loose connections rather than control board faults.

Jump to Common Problems

Most Common Problems on This Model

Parts That Commonly Fail

PartNotes
Upper thermostat and high-limit assemblyAmazon | Includes the red reset button and controls sequencing to the lower element
4,500-watt heating elements (copper)Amazon | Upper and lower, 240V, replace both if one has failed and tank is older than 5 years
Lower thermostatAmazon | Controls the lower element and receives power transfer from the upper thermostat
Electronic control board and displayAmazon | Manages vacation mode and fault reporting, verify all other components first before replacing

Water-Heater Error Codes for This Model

These codes apply to this model line:

When to Call a Pro

Call a licensed electrician or plumber if you are not comfortable working with 240-volt power, if you see burned or melted wire insulation inside the junction box, or if the breaker continues to trip after you have replaced elements and thermostats. Any work inside the access panels requires the breaker to be off and locked out, and you must verify zero voltage at all terminals before touching any wires. If the T&P valve is discharging or the tank is leaking from the shell, shut off power and water immediately and call a pro to evaluate whether the tank needs replacement. For gas line, burner, or igniter work, or if you ever smell gas, stop and call a licensed technician.