Yaskawa GA800 F033 - Causes & Fix

4 min read

Independent. We don't sell parts, so we tell you when not to buy one.

⚡ Quick Answer

F033 does not exist on Yaskawa GA800 drives. This code is specific to Allen-Bradley PowerFlex 525 and means auto-restart tries exceeded.

Pro repair
Difficulty Advanced
Est. time 1-3 hrs
Tools Multimeter , service manual, ESD strap

Yaskawa GA800 F033 — What It Means

There is no F033 fault code in the Yaskawa GA800 VFD manual or fault table. The F033 code belongs to Allen-Bradley PowerFlex 525 drives, where it indicates Auto Restart Tries Exceeded. This means the drive attempted to automatically restart after a fault but failed multiple times, reaching the maximum number of configured auto-restart attempts (typically set in parameter P151 or A541). F033 is always a secondary fault, so the root cause is another fault (such as overload, ground fault, or power loss) that triggered the auto-restart loop. If you see F033 on a display connected to equipment you believe is a Yaskawa GA800, verify the drive model number on the nameplate. You may have a PowerFlex 525 instead, or the display may be showing a fault from a different device in the system.

Before You Replace Anything

Technicians sometimes replace the drive itself when seeing F033, but the drive is rarely faulty. Disable auto-restart (set P151 to 0 on PowerFlex 525) to reveal the original fault code, then troubleshoot that root cause instead.

Jump to Fix

Common Causes

Quick Diagnosis

Answer these to narrow it down fast.

Does the nameplate on the drive say Yaskawa GA800 or Allen-Bradley PowerFlex?
Yes: If it says Allen-Bradley PowerFlex 525, consult PowerFlex documentation for F033 troubleshooting (auto-restart tries exceeded). If it says Yaskawa GA800, the F033 code is not valid for that model.
No: Take a photo of the complete nameplate and model number, then look up the correct fault code table for that specific drive model online or in the manual.
Is the display or HMI connected to more than one drive or controller?
Yes: Check each connected device individually to determine which one is actually faulting, as the F033 may be coming from a PowerFlex drive elsewhere in the system.
No: Focus troubleshooting on the single drive, but verify its brand and model first before proceeding with any fault code interpretation.
Does the Yaskawa GA800 manual list F033 in its fault code table?
Yes: Follow the manual's troubleshooting steps for that code (though this is extremely unlikely, as F033 is not a documented GA800 code).
No: The code does not exist for the GA800. Confirm the drive model, check for communication errors, and consult the correct manual for the actual drive you have.

Step-by-Step Fix

  1. Verify the drive brand and model by reading the nameplate on the front or side of the unit, noting the full model number and serial number.
  2. Check the fault code table in the operator manual for the exact model you identified, either in the printed manual or downloaded from the manufacturer’s website.
  3. If the drive is a PowerFlex 525, temporarily disable auto-restart by setting parameter P151 to 0, then clear the fault and restart to see the original root fault code instead of F033.
  4. Identify and troubleshoot the root fault shown after disabling auto-restart (common root faults include motor overload, ground fault, or power supply issues).
  5. Inspect motor and mechanical systems for grounded phases, shorted windings, blockages, or excessive load that would cause repeated faults.
  6. Check power supply quality with a multimeter or power quality analyzer, looking for low voltage, interruptions, or significant fluctuations outside the drive’s input voltage range.
  7. Test drive-to-motor wiring for shorts, ground faults, or open circuits using a megohmmeter and continuity tester, paying close attention to cable terminations and conduit entry points.

Parts Often Needed

PartNotes
Replacement componentAmazon | verify fitment for your exact model

When to Call a Pro

Call a qualified industrial electrician or drive technician immediately if you cannot verify the drive model, if the fault persists after confirming the correct drive documentation, or if troubleshooting reveals issues with high-voltage wiring, motor windings, or the drive’s internal components. VFD repair requires specialized test equipment, knowledge of power electronics, and adherence to lockout-tagout safety procedures. Never attempt to open or service a VFD cabinet without proper training, as lethal voltages can remain present even after disconnecting input power. A professional can also diagnose communication or network issues that may be causing fault codes from other devices to appear on a shared display.

Rough cost: A pro service call runs about $150-400 for diagnostics and repair of root cause.