Skip to content
Error Code Fixes
Go back

Yaskawa GA800 E62 Fault - Causes & Fix

4 min read

Independent. We don't sell parts, so we tell you when not to buy one.

⚡ Quick Answer

E62 is not a standard GA800 code format. Verify the exact display (E62, o62, or U62) on the keypad, check for loose connections, then reset.

Pro repair
Difficulty Advanced
Est. time 1-3 hrs
Tools Multimeter , service manual, ESD strap

Yaskawa GA800 E62 Fault — What It Means

The E62 code does not appear in verified Yaskawa GA800 fault code tables. Yaskawa drives typically display faults with an ‘o’ prefix (overcurrent, overvoltage) or ‘U’ prefix (undervoltage), so E62 may be a misread display, a communication alarm, or a code variant specific to your operator type. The GA800 troubleshooting process requires reading the exact code shown on the keypad or LED operator, identifying the root cause, and then pressing the RESET button to clear the fault after the problem is corrected.

Because the exact meaning of E62 cannot be confirmed from manufacturer documentation, start by verifying what the display actually shows. Check your drive’s model and catalog code on the nameplate, inspect for shipping damage or loose wiring, and consult the fault code table in your specific GA800 manual. If the drive continues to fault after reset, collect the model number, spec number, serial number, and failure information and contact Yaskawa support for interpretation.

Before You Replace Anything

Technicians sometimes replace the control board when the fault is actually caused by a loose cable or incorrect parameter setting. Always verify wiring, check the exact fault code in the manual, and test input power before ordering a new board.

Jump to Fix

Common Causes

Quick Diagnosis

Answer these to narrow it down fast.

Does the keypad clearly display 'E62' with no prefix letter?
Yes: The code may be a communication alarm or operator-specific message. Check your operator manual and verify all communication cable connections.
No: If you see 'o62' or 'U62', that is a standard Yaskawa fault format. Look up the exact code in the GA800 fault table in your manual.
Can you clear the fault by pressing RESET on the keypad?
Yes: The fault was transient. Monitor the drive during operation to see if it recurs, which would indicate an intermittent wiring or parameter issue.
No: The fault condition is still present. Power down, inspect all wiring and connections, verify input power, and check the drive nameplate for correct model selection.
Are all control and power cables secure with no visible damage?
Yes: The issue is likely internal to the drive or a parameter mismatch. Collect the model, serial, and spec number and contact Yaskawa support.
No: Reseat or replace damaged cables, then power up and attempt to reset the fault.

Step-by-Step Fix

  1. Write down the exact code displayed on the keypad or operator, including any prefix letter (o, U, E) and all digits.
  2. Locate the drive nameplate and record the complete model number, catalog code (C/C number), and serial number for reference.
  3. Inspect all wiring and connections for loose terminals, damaged insulation, or signs of shipping damage at the input power, motor, and control terminals.
  4. Press the RESET button on the keypad while the fault is displayed to attempt to clear the code after confirming wiring is secure.
  5. Consult the fault code table in your GA800 manual or technical documentation, searching for the exact code you recorded (E62, o62, or U62).
  6. Verify input power at the drive terminals matches the voltage and phase specifications on the nameplate.
  7. Contact Yaskawa technical support with your model number, serial number, and exact fault code if the manual does not list the code or the fault persists after reset.

Parts Often Needed

PartNotes
Yaskawa GA800 cooling fanAmazon | Replacement fan assembly if the drive has overheated and the control board has verified fan failure.
Yaskawa GA800 control boardAmazon | Replacement control PCB if the board has failed and displays corrupted or unlisted fault codes.

When to Call a Pro

Call a qualified drives technician or Yaskawa-authorized service provider if you cannot find E62 in your manual, if the fault returns immediately after reset, or if you are uncomfortable working with three-phase input power. The GA800 troubleshooting documentation states that only fan and control board components are supported for field replacement, so other internal repairs require factory service. A technician will verify the exact fault code, check for parameter mismatches, measure input and output voltages, and determine whether the drive needs a control board replacement or a complete unit exchange. Do not attempt to open the drive enclosure or measure high-voltage DC bus points without proper training and PPE.

Rough cost: A pro service call runs about $200–500 for service call and diagnostics.


🔧 Need a professional? Get free quotes from certified HVAC contractors near you.
Get Free Quotes →
Share this post on:

Previous Post
Yaskawa GA800 E65 Fault - Causes & Fix
Next Post