⚡ Quick Answer

E32 on Yaskawa GA800 means soft-charge bypass relay answerback fault. Most often caused by worn relay or failed control board.

Difficulty Advanced
Est. time 1-3 hrs
Tools Multimeter , service manual, ESD strap

Yaskawa GA800 E32 Fault — What It Means

The E32 fault on a Yaskawa GA800 variable frequency drive indicates a soft-charge bypass relay answerback fault. During startup, the drive commands the soft-charge bypass relay to change state and monitors a feedback signal to confirm the relay responded correctly. When E32 appears, the drive did not receive the expected relay-state feedback from the DC bus precharge or bypass circuit. This is not a motor overload or output short. It is a precharge relay feedback problem specific to the drive’s internal startup sequence. The drive expects confirmation that the relay closed or opened as commanded, and that signal was missing or incorrect.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Power down completely, lock out, and tag the disconnect for the VFD before opening any enclosure or inspecting internal components.
  2. Inspect all control and relay wiring for loose connectors, signs of overheating, and visible damage to the relay or control board areas.
  3. Re-energize the drive once to verify whether the fault is persistent or intermittent, then immediately power down again for safety.
  4. Check parameter U4-06 (precharge relay maintenance counter) if accessible, and note any high-hour or end-of-life indication for the soft-charge relay.
  5. Inspect the soft-charge bypass relay or contactor for physical wear, pitting on contacts, or failure to actuate, and replace if accessible and visibly degraded.
  6. Replace the control board if the relay tests good but feedback signal paths appear faulty, or if the fault persists after relay replacement.
  7. Contact Yaskawa support with model number, serial number, fault code, application details, and time in service if the fault is not resolved by field-replaceable parts or if the drive requires factory repair.

Parts Often Needed

PartNotes
Yaskawa GA800 soft-charge bypass relayAmazon | Precharge circuit relay, confirm part number for your drive frame size
Yaskawa GA800 control boardAmazon | Replacement board for relay drive and feedback circuits, specify drive model
Replacement Yaskawa GA800 VFDAmazon | If relay circuit is not field-serviceable or multiple internal faults exist

When to Call a Pro

Call a qualified VFD service technician or contact Yaskawa technical support if you are not trained in high-voltage industrial drive repair, if the fault persists after inspecting wiring and connections, or if you do not have access to the drive’s internal relay and control board assemblies. Precharge circuits operate at DC bus voltages and require proper lockout, discharge, and measurement procedures. If the drive is mission-critical or under warranty, professional diagnosis and factory-authorized parts will prevent further damage and make sure safe restoration of operation.