⚡ Quick Answer

E10 on Yaskawa GA800 means external fault input active. Check interlock wiring, overload relays, and external safety contacts.

Difficulty Advanced
Est. time 1-3 hrs
Tools Multimeter , service manual, ESD strap

Yaskawa GA800 E10 Fault — What It Means

E10 on a Yaskawa GA800 VFD indicates an external fault input has been triggered. This is not an internal drive hardware failure. Instead, the drive has detected an open contact or active signal from an external protective device or interlock circuit, causing it to shut down. The fault comes from outside the VFD itself, such as a motor overload relay, pressure switch, thermal protector, safety relay, or other customer-supplied protective equipment in the control circuit.

The GA800 is responding to a condition in your external wiring or a device telling it to stop, not reporting a problem with its own power section or control boards. Diagnosis starts with the machine schematic and the external input chain, not the drive internals. You need to identify which external device or wiring issue opened the fault input circuit and restore normal operating conditions before clearing the fault.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Obtain the machine schematic and terminal plan to identify which external devices are wired into the GA800 fault input circuit and where they are physically located.
  2. Inspect all external protective devices one by one, including motor overload relay contacts, pressure switches, flow switches, thermal protectors, and safety relay contacts, to determine if any have tripped or opened.
  3. Check control circuit wiring and terminal connections at the drive’s external fault input terminals for loose screws, broken wires, open circuits, or missing control voltage.
  4. Verify drive parameter settings match the intended control method and confirm the external fault input is configured correctly for your wiring scheme and logic type.
  5. Reseat option cards and inspect connectors if the E10 is part of a networked or option-based control system, checking for bent pins or poor contact.
  6. Restore the external trip circuit to normal by correcting the open contact, repairing wiring, or resetting the protective device, then clear the E10 fault from the drive keypad or control interface.
  7. Test-run the system and monitor for fault recurrence. If E10 returns immediately with all external wiring and devices proven good, suspect a drive input board issue or contact Yaskawa technical support for board-level diagnostics.

Parts Often Needed

PartNotes
Motor overload relayAmazon | Replace if contacts are burned, stuck open, or mechanically failed after tripping.
Pressure or flow switchAmazon | Replace if defective or falsely tripping the external fault input.
Control wiring and terminal blocksAmazon | Replace damaged conductors or terminals in the external fault input circuit.
GA800 option card or I/O boardAmazon | Only if all external devices check good and fault persists after reseating. Consult Yaskawa support for part number.

When to Call a Pro

Call a qualified electrician or controls technician if you are not trained to read machine schematics, trace control circuits, or work safely with industrial control voltage. If you have verified all external wiring, contacts, and protective devices are in good condition and the E10 fault returns immediately after clearing, the issue may be in the drive’s input board or require factory-level diagnostics. Contact Yaskawa technical support or an authorized service center for board replacement and advanced troubleshooting. Do not attempt to bypass safety interlocks or jumper the external fault input to clear the code, as this can create a hazardous operating condition.