Weil-McLain Boiler E13 Error — Low Water Pressure Fix & Diagnosis

⚡ Quick Answer

Weil-McLain boiler error E13 means the low water cutoff or pressure switch detected insufficient water. Step-by-step diagnosis, fill procedures, and repair guidance for Ultra, Evergreen, GV90+, CGs, LGB, and WGO boilers.

⚡ AT A GLANCEScroll down for full repair guide
What it meansWeil-McLain boiler error E13 means the low water cutoff or pressure switch detected insufficient water. Step-by-step diagnosis, fill procedures, and repair guidance for Ultra, Evergreen, GV90+, CGs, LGB, and WGO boilers.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
Repair time10-45 minutes for basic checks
Repair intent

Need this fixed instead of diagnosed?

Weil-McLain boiler error E13 means the low water cutoff or pressure switch detected insufficient water. Step-by-step diagnosis, fill procedures, and repair guidance for Ultra, Evergreen, GV90+, CGs, LGB, and WGO boilers.

Error Code: Weil-McLain Boiler E13

What it means: Error E13 on Weil-McLain boilers indicates the boiler sensed insufficient water. The low water cutoff (LWCO) or pressure switch detected that water level or pressure dropped below the minimum safe operating threshold. The control board responds by shutting down the burner and displaying E13 to prevent dry-fire damage to the heat exchanger.

E13 appears across multiple Weil-McLain boiler platforms: Ultra series, Evergreen, GV90+, CGs, LGB, and WGO models. The diagnostic path differs slightly depending on whether your boiler uses a mechanical LWCO probe or a pressure transducer, but the underlying principle is the same. The boiler thinks it does not have enough water to operate safely.

Normal System Pressure

A properly filled hot water heating system should maintain these pressure ranges:

ConditionPressure (PSI)Notes
Cold system (60-70°F)12-15 PSINormal fill pressure for most residential systems
Hot operating (160-200°F)15-25 PSIPressure rises with temperature
Below 12 PSI (cold)E13 likelySystem needs water
Above 30 PSI (hot)Pressure relief valve opensExpansion tank or fill valve problem

Check the mechanical pressure gauge mounted on the boiler supply piping. If the gauge reads below 12 PSI when the system is cold, start with the fill valve procedure below. If the gauge shows normal pressure but E13 still appears, the issue is likely sensor-related.

Common Causes

Step-by-Step Diagnosis

Step 1: Verify the Pressure Gauge Reading

Look at the boiler pressure gauge. If it reads 0-10 PSI when cold, the system needs water. If it reads 12-15 PSI or higher but E13 is still displayed, skip to Step 4.

Step 2: Add Water to the System

Locate the manual fill valve. It is typically a lever or gate valve on the cold water supply line entering the boiler, often near the auto-fill valve. Open it slowly while watching the pressure gauge. Fill to 15-18 PSI for a typical two-story home. Close the valve completely when pressure reaches the target.

For boilers with an automatic fill valve (Watts 1156F, Sparco, or equivalent), you may hear the valve open automatically when pressure drops. If the auto-fill does not open and you have no manual bypass, the valve has failed and needs replacement.

Step 3: Bleed Air from the System

After adding water, purge any trapped air. Open the highest radiator or baseboard bleed valve in the house until a steady stream of water flows. Work down to lower floors, bleeding each zone. Air trapped in the system mimics low-water conditions by preventing proper circulation.

Step 4: Inspect for Leaks

Walk the entire system while it is cold and pressurized. Check every fitting, circulator pump shaft seal, zone valve body, and radiator valve. Look for drips, rust trails, water stains on floors, or green oxidation on copper fittings. A leak that drips once every 10 seconds can drop system pressure by several PSI per week.

Step 5: Test the Expansion Tank

With the system cold and the boiler off, press the Schrader valve core on the expansion tank’s air fitting. If water sprays out, the bladder has ruptured. Replace the tank. If air comes out, check the pre-charge pressure with a tire gauge. It should match the system’s cold fill pressure (typically 12 PSI for ground floor). Add air with a compressor if low.

Step 6: Clean the LWCO Probe

On Ultra, Evergreen, and GV90+ models with a conductance probe in the boiler return header, scale buildup causes false low-water readings. Drain the boiler below the probe level, remove the probe (typically 1/2” NPT), and wipe it clean with a fine abrasive pad or emery cloth. Reinstall and refill.

Step 7: Check the Pressure Sensor

If the gauge reads normal pressure, the expansion tank is fine, the probe is clean, and E13 still appears, the pressure transducer or pressure switch may have failed. Test by measuring resistance or voltage across the sensor according to the Weil-McLain manual for your specific model. A failed sensor reads open or shorted.

Code Reference Table

CodeModel SeriesMeaningCommon Fix
E13Ultra, EvergreenLow water cutoff tripped / insufficient waterFill system, clean LWCO probe
E13GV90+Pressure switch detected low waterFill system, check pressure switch
E13CGs, LGB, WGOLWCO open / low water conditionFill system, inspect for leaks
E10All modelsLow water pressure warning (below 10 PSI)Add water, check fill valve
E14UltraExternal limit device openCheck rollout switch, blocked vent switch

When to Call a Professional

E13 is a safety shutdown. Never attempt to bypass the low water cutoff or operate the boiler with confirmed low water. Dry-firing a cast iron or aluminum heat exchanger will destroy it within seconds.

Call a licensed technician if:

For Weil-McLain Ultra and Evergreen boilers, the control board records a fault history. A technician can pull the logs to see exactly how many times E13 appeared and at what system pressures. This helps distinguish a real low-water condition from a sensor fault.

Need Replacement Parts?

Finding the right replacement parts for your equipment is critical to getting it running again. Check current prices on Amazon . Prices and availability change frequently.


Need a professional? Compare certified HVAC repair options before replacing parts.