Error code A60

Weil-McLain A60 Error Code - Causes & Fix

4 min read

Independent. We don't sell parts, so we tell you when not to buy one.

⚡ Quick Answer

A60 is not a standard Weil-McLain code. Check your control's fault-history menu for the real lockout code and consult your model manual.

Difficulty Pro recommended
Est. time 1-3 hrs

Weil-McLain A60 Error Code — What It Means

Weil-McLain does not publish a standard A60 error code in manufacturer documentation for its residential or commercial boiler lines. The code may be model-specific, a display artifact, or a misread fault. Weil-McLain controls typically store fault history in a diagnostics menu accessible through button sequences on the control board. The actual lockout or fault code will appear as a numeric fault code or text string that corresponds to entries in your model’s installation and service manual.

Because A60 cannot be verified against manufacturer fault tables, the first step is to access the stored fault history on your boiler’s control, write down the exact code and any accompanying text, then cross-reference it with the service section of your model’s manual. Common Weil-McLain fault categories include ignition failure, flame-proving problems, low system pressure, proof-of-flow issues, limit trips, and venting or combustion faults, but each has a defined code that varies by control platform and model family.

Before You Replace Anything

Homeowners often replace the control board when the real problem is a misread code or a simple sensor fault. Always retrieve the stored fault history from the control’s diagnostics menu and compare it to the manual before ordering parts.

Jump to Fix

Common Causes

Quick Diagnosis

Answer these to narrow it down fast.

Does the control display a flashing or steady LED lockout pattern?
Yes: The boiler is in lockout. Access the fault-history menu using the button sequence in your manual and note the stored fault code for lookup.
No: The display may be showing a status message or service reminder rather than a fault. Verify system pressure and check for a call for heat before investigating further.
Can you retrieve a stored fault history from the control's diagnostics menu?
Yes: Write down the exact fault code and text, then cross-reference it with the service section of your model's manual or call a technician with that code.
No: Consult your installation manual for the button sequence to enter diagnostics mode, or contact Weil-McLain support with your model and serial (CP) number for guidance.
Is system fill pressure below 12 psi or above 25 psi on the gauge?
Yes: Low pressure can cause a lockout on many models. Check for leaks, refill to the recommended cold pressure, and reset the boiler once.
No: Pressure is normal. The fault is likely ignition, flame-sensing, venting, or a control issue that requires professional diagnosis.

Step-by-Step Fix

  1. Turn off power to the boiler at the service switch or circuit breaker and wait 30 seconds.
  2. Restore power and observe the control display. Note any flashing LED patterns or alternating code displays.
  3. Access the fault-history menu by pressing and holding the button sequence specified in your model’s installation manual (often a combination of reset and mode buttons).
  4. Write down the exact fault code and any accompanying text from the stored history, including the number of occurrences and timestamps if shown.
  5. Cross-reference the code with the fault table in your model’s service manual or contact Weil-McLain technical support with your model number and CP (serial) number.
  6. Check system fill pressure on the boiler’s pressure gauge. If below 12 psi, locate the fill valve and bring pressure to the recommended cold setting (typically 12-15 psi for residential systems).
  7. Attempt a single reset only if you have confirmed system pressure is correct and no other safety issues are present. If the fault recurs immediately or within one cycle, call a qualified heating technician for diagnosis and repair.

Parts Often Needed

PartNotes
Weil-McLain control board (model-specific)Amazon | Only replace after retrieving the stored fault code and confirming board failure with a technician or manufacturer support.
Flame sensor or igniter assemblyAmazon | Common replacement if the stored fault indicates ignition or flame-proving failure.

When to Call a Pro

Call a licensed heating technician immediately if you cannot retrieve a stored fault code from the control’s diagnostics menu, if the boiler is in lockout and you are unfamiliar with gas appliance troubleshooting, or if the fault recurs after a single reset. Gas-fired boiler repair requires proper combustion analysis, gas-pressure testing, and electrical diagnostics that are beyond typical DIY scope. A technician will use the control’s fault history, measure gas pressure and flame current, inspect the burner and heat exchanger, and verify venting and airflow to identify the root cause. Do not repeatedly reset a lockout without identifying the fault, as ignition or flame-proving problems can create unsafe combustion conditions or carbon-monoxide risk.

Rough cost: A pro service call runs about $150-400.