Weil-McLain Boiler A138 Error - Causes & Fix

4 min read

Independent. We don't sell parts, so we tell you when not to buy one.

⚡ Quick Answer

A138 is not a standard Weil-McLain fault code. Check your model manual to identify the exact meaning before replacing any parts.

Difficulty Pro recommended
Est. time 1-3 hrs

Weil-McLain Boiler A138 Error — What It Means

The A138 code is not a manufacturer-universal fault code documented in standard Weil-McLain service manuals. It is likely a model-specific or control-platform-specific service code or history entry. Weil-McLain boilers use different control systems across their product lines, and each controller can display unique diagnostic codes. The exact meaning of A138 must be confirmed from your specific boiler’s installation and service manual or from the control manufacturer’s documentation before you attempt any repair.

Because the code is not universally defined, the root cause could involve a temperature sensor, flame detection issue, stuck relay, circulation problem, or condensate drainage fault. These are common fault categories on Weil-McLain boilers, but you should not replace parts based on guesswork. Retrieve the fault history from the diagnostic menu, record the operating conditions when the fault occurred, and cross-reference the code in your model’s manual to identify the failed component.

Before You Replace Anything

Many technicians replace the control board or flame sensor first when they see an unfamiliar code. Pull the fault history from the diagnostic menu and test the suspected sensor or relay electrically with a meter before ordering parts.

Jump to Fix

Common Causes

Quick Diagnosis

Answer these to narrow it down fast.

Is the system water pressure below 12 psi on the gauge?
Yes: Fill the system to about 15 psi cold and reset the boiler. If the code clears, you may have a slow leak or expansion-tank problem.
No: Pressure is normal. Continue to the next check.
Can you enter the diagnostic menu and see a fault history or lockout list?
Yes: Write down all stored codes and their time stamps, then look up each code in your model's service manual to find the specific fault name and corrective action.
No: You may not have access to the advanced menu. Call a technician who can retrieve the history and interpret the codes correctly.
Does the boiler run continuously or fail to shut off when the thermostat is satisfied?
Yes: A stuck relay or failed control output is likely. This requires electrical testing and relay replacement by a qualified technician.
No: The fault is probably intermittent or related to a sensor. Pull the fault history and test the suspected sensor before replacing it.

Step-by-Step Fix

  1. Identify your exact boiler model and control type from the rating plate or control display before doing anything else.
  2. Enter the contractor or diagnostic menu following the procedure in your model’s manual and retrieve the past faults and lockout history.
  3. Record the A138 code, any other active codes, the time stamps, and the operating conditions when each fault occurred.
  4. Look up each code in your boiler’s installation and service manual or contact Weil-McLain technical support to get the verified fault name and recommended corrective action.
  5. Check the obvious system conditions first: thermostat demand, power, gas supply, water pressure (target about 15 psi cold), circulator operation, and any blocked intake, exhaust, or condensate drain.
  6. Test the suspect component electrically with a multimeter if the fault points to a temperature sensor, low-water sensor, or relay. Compare your readings to the values in the service manual.
  7. Replace only the verified failed component using the correct part number from the manual or parts diagram, then clear the fault, restore operation, and verify a full heat cycle under load.

Parts Often Needed

PartNotes
Temperature sensor or thermistorAmazon | Match the part number to your exact boiler model and control platform.
Flame sensor or igniter assemblyAmazon | Clean the sensor first. Replace only if testing confirms failure.
Control relay or control boardAmazon | Weil-McLain service example uses 24 V relay part number 510-35223 for some models. Verify your model’s part number before ordering.

When to Call a Pro

Call a qualified heating technician if you cannot access the diagnostic menu, if the fault history shows multiple unrelated codes, if you do not have the service manual for your specific model, or if electrical testing and relay or sensor replacement are beyond your skill level. Gas-fired boiler work involves combustion safety, venting, and electrical controls that require proper training and test equipment. Incorrect diagnosis or part replacement can leave the system unsafe or cause repeated failures. A technician can retrieve the fault history, cross-reference the A138 code in the correct manual, test the suspected component, and replace only the failed part with the manufacturer-approved part number.

Rough cost: A pro service call runs about $200-450.