Higher-cost part to price only after power, sensor, and wiring checks.
Trane error code 79 on the XV20i variable-speed heat pump means a communication fault — the outdoor unit is not receiving valid communications from the ComfortLink II thermostat or the air handler/furnace control board. The XV20i uses a proprietary two-wire communicating system (Trane’s ComfortLink II or Nexia system). Code 79 indicates the outdoor unit dropped off the communication bus, which typically prevents the system from operating in heating or cooling mode.
| Part | Notes |
|---|---|
| ComfortLink II thermostat | Replace when thermostat communication circuit has failed |
| Outdoor unit control board | Replace after lightning strike or if board shows burn marks |
| Communication wire (18-gauge, 2-conductor) | Replace entire run if wire is damaged; don’t splice communication wire |
| Air handler control board | Replace if air handler shows its own separate communication fault |
For Trane heat pump and air-conditioner faults, confirm thermostat demand, outdoor board history, sensor resistance, airflow, coil condition, and refrigerant-pressure conditions before replacing controls or motors.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Trane ComfortLink II system diagnostics require the Trane proprietary service tool (TechView) to read detailed fault history and communication bus diagnostics. If component swapping doesn’t resolve code 79, an authorized Trane dealer with TechView can isolate the exact failure point.