State Water Heater E170 Error Code - Causes & Fix

3 min read
⚡ Quick Answer

E170 means your State water heater detected dangerously high water temperature and locked out. Most often caused by scale buildup or blocked venting.

Difficulty Pro recommended
Est. time 1-3 hrs

State Water Heater E170 Error Code — What It Means

E170 is an overheat fault. Your State water heater’s control system has detected that water temperature exceeded its safety limit, so it locked out to protect the unit and your home. The controller saw a temperature reading above the allowed threshold and stopped normal operation to prevent damage or scalding.

This code typically signals a real problem with heat transfer, airflow, or sensing rather than a transient glitch. The fault can appear on both tank-type and tankless models, though the underlying causes differ slightly by platform.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Turn off hot-water demand at all fixtures and let the water heater cool for at least 30 minutes, then verify the E170 fault is still present on the display.
  2. Inspect the venting and air intake for blockages, damaged piping, disconnected joints, or debris, and clear any restrictions you find because airflow problems can directly cause overheating.
  3. Check water flow by cleaning the inlet screen or filter, confirming that both isolation valves are fully open, and verifying adequate supply pressure with no downstream restrictions.
  4. Flush and descale the heat exchanger following the manufacturer’s approved procedure if you see signs of mineral buildup or if you are in a hard-water area.
  5. Test the temperature sensor or thermistor using a multimeter to check resistance or continuity against the specifications in your model’s service manual, and replace it if readings are out of range or unstable.
  6. Reset the control board after correcting the underlying cause, then monitor the unit under normal load for at least one full heating cycle to confirm the code does not return.
  7. Escalate to advanced diagnostics if the fault recurs, including control-board input verification, combustion-air delivery checks, and internal safety-limit inspection.

Parts Often Needed

PartNotes
Temperature sensor (thermistor)Amazon | Replace if resistance readings are out of spec or the sensor tests intermittent.
Inlet water filter or screenAmazon | Clean or replace if clogged and restricting flow into the heater.
Heat exchanger assemblyAmazon | Required only if severe scale damage or overheating has permanently compromised heat transfer and flushing does not restore operation.
Control boardAmazon | Replace only after verifying all sensors and field wiring test correctly but the fault persists.

When to Call a Pro

Call a licensed plumber or water-heater technician if you are not comfortable working with gas or electrical connections, if the fault returns after you have cleared blockages and flushed the system, or if you lack the tools to test sensors and control inputs. Overheat faults can indicate combustion or venting problems that require proper diagnostic equipment and code-compliant repairs. A qualified pro can perform a full descale service, verify safe combustion air delivery, and confirm that all safety limits are operating correctly before returning the unit to service.