Skip to content
Industrial Error Code Fixes
Go back

State Water Heater E100 Error Code - Causes & Fix

2 min read
⚡ Quick Answer

E100 means ignition failure on your State tankless heater. Most often caused by a blocked air intake screen or dirty inlet water filter.

Difficulty Pro recommended
Est. time 1-3 hrs

State Water Heater E100 Error Code — What It Means

The E100 code on a State tankless water heater signals an ignition failure or no-ignition lockout. The unit attempted to start its burner but could not prove flame during the ignition sequence. This fault is most commonly tied to blocked air intake screens, restricted gas supply, or low water flow through a clogged inlet filter. The heater enters a safety lockout to prevent unburned gas from accumulating.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Turn off power and gas at the dedicated shutoffs before beginning any inspection or cleaning work.
  2. Inspect the air intake screen on the front or side of the unit and remove any lint, dust, or blockage with a soft brush or vacuum.
  3. Remove and clean the inlet water filter at the cold-water connection using a soft brush and running water to clear sediment or debris.
  4. Verify gas supply: confirm the gas cock is fully open, check that the correct fuel type is connected, and look for any kinks or undersized pipe upstream.
  5. Check the exhaust vent for obstructions, proper termination clearance, and compliance with the installation manual’s length and elbow limits.
  6. Clean the flame rod and igniter assembly by removing the burner cover and gently wiping the sensor surfaces with fine sandpaper or a clean cloth.
  7. Restore power and gas, then test by opening a hot-water tap and watching for normal ignition. If E100 returns, note the symptom and call a qualified technician for combustion diagnostics.

Parts Often Needed

PartNotes
Inlet water filter screenAmazon | Original State or A. O. Smith part matched to your model’s inlet connection size.
Flame rod and igniter assemblyAmazon | Required when cleaning does not restore reliable flame sensing. Verify part number from your model label.
Air intake and vent pipe kitAmazon | Use only if the existing vent system is damaged, improperly sized, or does not meet current installation codes.

When to Call a Pro

Call a licensed plumber or gas technician if the E100 code persists after you have cleaned the air intake, inlet filter, and flame rod. Diagnosing low gas pressure, testing ignition voltage, adjusting combustion air settings, or replacing the gas valve or control board requires specialized tools and training. Ignition faults that recur after basic cleaning often point to improper venting, incorrect gas piping, or a failing ignition module that must be tested under load by a qualified professional.


Share this post on:

Previous Post
State Water Heater E111 Error Code - Causes & Fix
Next Post
State Water Heater E88 Error Code - Causes & Fix