SPX Flow Pump Fault Codes: Complete Guide

⚡ Quick Answer

SPX Flow pump fault codes and diagnostics. Fault codes for Bran+Luebbe, Lightnin, and Delco pumps, causes, and technician-level troubleshooting.

SPX Flow Pump Fault Codes

SPX Flow (formerly incorporating Bran+Luebbe, Lightnin, Plenty Mirrlees, Delco) produces a wide range of industrial pumps for chemical processing, food/beverage, and utilities. Fault detection is typically through the associated motor protection relay or VFD ΓÇö the pump itself does not generate electronic codes.

SPX Flow Pump Fault Reference

Fault IndicationFault DescriptionCommon CauseAction
Motor trips/overloadMotor thermal tripOverload, high viscosity fluid, worn impellerCheck FLA vs. nameplate
Vibration highExcessive vibrationCavitation, bearing, alignmentCheck vibration levels
Pressure relief openRelief valve ventingDischarge blockage, closed valveCheck discharge system
Seal leakMechanical seal failureWorn seal or improper installationReplace mechanical seal
No flowPump running, no outputAir lock, blocked suction, wrong rotationCheck suction and rotation
Noise (cavitation)Cavitation damageInsufficient NPSHCheck suction conditions
Bearing overtempHigh bearing temperatureLubrication, overload, misalignmentCheck lubrication schedule
Output lowBelow rated outputWorn impeller, high viscosityInspect impeller wear rings

Most Common SPX Flow Faults

Motor Overload

SPX Flow pumps handling high-viscosity fluids (such as Bran+Luebbe metering pumps on chemicals) are susceptible to overload if fluid viscosity increases. Check fluid temperature ΓÇö colder, more viscous fluids draw higher current. Check the motor protection relay trip current setting matches the motor nameplate.

Seal Leak

Most SPX Flow centrifugal and positive displacement pumps use mechanical seals. Seal failure is typically caused by excessive shaft runout, dry run, wrong seal material for the fluid, or abrasive particles in the fluid. Inspect the seal gland for liquid weepage or crystallized chemical deposits.

No Flow ΓÇö Air Lock

Centrifugal pumps require priming. If air enters the suction line, the pump continues to run but produces no flow or very low head. Install a foot valve on vertical suction lifts, verify suction pipe is fully submerged, and prime via the vent valve on the pump casing.

Cavitation

Cavitation occurs when suction pressure drops below the fluid’s vapor pressure. Required NPSH must exceed available NPSH. Check suction strainer for blockage (most common cause), reduce suction line length/fittings, or reduce pump speed.

Parts Commonly Needed

PartNotes
Mechanical sealAmazon | Match shaft diameter and material
Impeller wear ringsAmazon | Replace as sets
Bearing setAmazon | Match pump specification
Suction strainer basketAmazon | Clean or replace regularly
Motor protection relayAmazon | Match FLA and trip class

Pro tip: SPX Flow provides PumpView and other IIoT monitoring tools for their pumping equipment. For process-critical applications, condition-based monitoring with vibration and temperature sensors is more cost-effective than scheduled replacement of bearings and seals.