Skip to content
Industrial Error Code Fixes
Go back

Rinnai RUR Series Error Codes — Tankless Water Heater Fault Guide

⚡ Quick Answer

Rinnai RUR Series Error Codes - Tankless Water Heater Fault Guide: likely causes, checks, and repair decisions before replacing parts.

⚡ AT A GLANCEScroll down for full repair guide
What it meansRinnai RUR Series Error Codes - Tankless Water Heater Fault Guide: likely causes, checks, and repair decisions before replacing parts.
Most likely causeMost plumbing faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededTemperature sensor
Repair intent

Need this fixed instead of diagnosed?

Rinnai RUR Series Error Codes - Tankless Water Heater Fault Guide: likely causes, checks, and repair decisions before replacing parts.

Likely parts to price

Price the common parts before you book service.

Temperature sensor

Common error-code part. Confirm resistance and connector style.

Thermistor

Useful to price for temperature-reading faults.

Thermal fuse

Low-cost safety part for heat and no-start symptoms.

Rinnai RUR Series Error Codes — What They Mean

The Rinnai RUR series (RUR160iN, RUR199iN, RUR160eN, RUR199eN) are condensing tankless water heaters with efficiency ratings up to 0.96 UEF. They display fault codes on the controller (MC-91-2 or equivalent). The RUR series uses PVC venting and produces condensate, distinguishing it from the non-condensing RL and RV series. Errors appear on the remote controller display.

Jump to Fix

Rinnai RUR Series Error Code Reference

CodeMeaning
02Bypass flow control fault
10Exhaust air temperature sensor fault
11Ignition failure
12Flame failure during operation
14Thermal fuse (overtemp) tripped
16Overtemp — maximum outlet temperature exceeded
25Condensate neutralizer/drain fault
31Combustion air inlet sensor fault
32Outlet water temperature sensor fault
33Heat exchanger outlet sensor fault
52Modulating gas valve error
61Fan/combustion air fault
65Water flow adjustment fault
71Gas valve solenoid fault
72Flame sensor fault
79Water temperature mismatch

Common Causes by Code

Step-by-Step Fix

  1. Read the code from the remote controller — The MC-91-2 remote shows the error code on the display. Note the code before resetting.
  2. For Code 11 — Check gas supply pressure at the RUR inlet (should be 3.5–7” W.C. for NG, 8–14” W.C. for LP). Inspect the PVC air intake termination outdoors — the combustion air inlet must be clear of snow, ice, and debris.
  3. For Code 12 — Inspect the condensate drain slope and confirm the drain line exits freely. If condensate is backing up inside the unit, it can quench the flame.
  4. For Code 14 — Locate the thermal fuse (single-use; flat rectangular component in the exhaust path). Test for continuity — no continuity means it has blown. Replace only after identifying and correcting the root cause.
  5. For Code 25 — Find the condensate drain outlet (PVC pipe from the bottom or side of the unit). Confirm it drains to an appropriate floor drain or condensate pump. Clear any blockage with warm water.
  6. For Code 61 — Listen to the fan during startup. The RUR fan should spin up and reach operating speed within 15 seconds. A high-pitched bearing noise followed by Code 61 indicates a worn bearing.
  7. Reset — Press the ON/OFF button on the remote controller to reset after correcting the fault. For Code 14, the thermal fuse must be replaced — the unit will not operate until continuity is restored.

Parts Often Needed

PartNotes
Thermal fuseOne-time device; investigate cause before replacing
Combustion fan assemblyFor Code 61; includes wheel
Gas valveFor Code 71 with confirmed 24V signal
Flame sensor rodFor Code 72; clean first
Condensate drain trapCheck for blockage or replace if cracked
Remote controller (MC-91-2)If display is faulty or communication fails

Need Replacement Parts?

Before ordering, match the water-heating part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

Thermal fuse replacement and gas valve diagnosis require licensed plumbing and/or gas technicians in most jurisdictions. If Code 14 has tripped, do not simply replace the fuse and restart — the underlying cause (heat exchanger scale, blocked flue) must be corrected. Contact Rinnai technical support (1-800-621-9419) for warranty assistance.


Share this post on:

Previous Post
Rinnai CBU Combi Boiler Error Codes — Complete Fault Guide
Next Post
Noritz Error Code 20 — Low Water Flow