Quincy QGS Compressor Fault Codes: Complete Guide

⚡ Quick Answer

Quincy QGS rotary screw compressor fault codes and diagnostics. Intellizone II fault codes, causes, and technician-level troubleshooting.

Quincy QGS Compressor Fault Codes

Quincy QGS rotary screw compressors use the Intellizone II controller. Fault codes and messages display on the Intellizone panel LCD. The controller stores fault history with run hours and timestamps.

QGS Fault Code Table

Code/MessageFault DescriptionCommon CauseAction
HIGH TEMPHigh discharge temperatureDirty cooler, low oil, high ambientClean cooler, check oil
HIGH TEMP WARNTemperature approaching limitPre-shutdown warningClean cooler immediately
MOTOR OVERLOADMotor thermal tripExcessive current or loadCheck motor amps and load
HIGH PRESSURESystem pressure too highExcessive demandCheck pressure setting
LOW OIL PRESSUREOil pressure insufficientLow oil or failed pumpCheck oil level and pump
PHASE LOSSMissing supply phaseFuse or supply faultCheck input power
INLET RESTRICTIONDirty inlet filterRestricted air intakeReplace inlet filter
EMERGENCY STOPE-stop activeE-stop circuit openCheck E-stop wiring
CHECK SEPARATORSeparator element pressure drop highDirty separatorReplace separator element
SERVICE DUEMaintenance interval reachedHours elapsedPerform scheduled PM
SENSOR FAULTFailed temperature sensorOpen or shorted sensorReplace thermistor
AUTO DRAIN FAULTCondensate drain valve faultSolenoid valve failureCheck drain valve

Most Common QGS Faults

HIGH TEMP

Quincy QGS compressors have a high-temperature shutdown at typically 228┬░F (109┬░C). The most common cause is a dirty oil cooler or air aftercooler. Blow fins clean with low-pressure air. On larger QGS models, the cooler can be removed for power washing with degreaser.

MOTOR OVERLOAD

Check that the motor overload relay is set correctly: current setting should be 100ΓÇô105% of motor nameplate FLA. Verify three-phase voltage balance ΓÇö more than 3% imbalance causes disproportionate current in one phase.

CHECK SEPARATOR ΓÇö Separator Element

When separator differential pressure exceeds design maximum (typically 10 PSI), this alarm triggers. The separator element is a wear item ΓÇö replace at the scheduled interval (typically 4,000 hours). A clogged separator element increases discharge temperature and reduces compressor efficiency.

AUTO DRAIN FAULT

Quincy QGS has an electronic auto-drain to remove condensate from the separator tank. If the solenoid valve fails (stuck closed = water in oil; stuck open = air loss), this fault triggers. Check solenoid valve coil resistance and verify 24 VAC at coil during drain cycle.

Parts Commonly Needed

PartNotes
Inlet air filterAmazon | Model-specific
Oil/separator elementAmazon | Replace per service schedule
Quincy QGS oilAmazon | Synthetic ΓÇö match model specification
Auto-drain solenoidAmazon | Check coil resistance
Temperature thermistorAmazon | NTC type ΓÇö check resistance vs. temp chart
Motor overload relayAmazon | Match FLA setting

Pro tip: Quincy QGS Intellizone II logs the last 10 faults with run hours. Access via MENU → HISTORY → FAULT LOG on the panel. If HIGH TEMP faults are increasing in frequency, track the interval between faults — progressive reduction in time between faults indicates a degrading cooler before total failure.