LG Window AC CH02 Error Code — Indoor Thermistor Fault

⚡ Quick Answer

Fix LG window AC CH02 error code indicating an indoor evaporator thermistor fault with these simple repair steps.

⚡ AT A GLANCEScroll down for full repair guide
What it meansFix LG window AC CH02 error code indicating an indoor evaporator thermistor fault with these simple repair steps.
Most likely causeMost window-ac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
Repair time10-45 minutes for basic checks
Repair intent

Need this fixed instead of diagnosed?

Fix LG window AC CH02 error code indicating an indoor evaporator thermistor fault with these simple repair steps.

LG Window AC CH02 Error Code — Indoor Thermistor Fault

Your LG window air conditioner flashes CH02 on the display. The unit stops cooling. This is an indoor evaporator thermistor fault. Here is what it means and how to fix it yourself.

Quick Reference

CodeMeaningSeverityDIY Fixable?
CH02Indoor evaporator coil temperature sensor faultModerateYes — sensor replacement

What CH02 Means

The CH02 error code tells you the evaporator coil temperature sensor (also called the indoor thermistor) is not sending a signal the control board can read. This sensor sits embedded in the evaporator coil fins. It tells the board when the coil is cold enough to start running the fan and when it is getting too cold and might freeze.

When this sensor fails, the control board cannot know the coil temperature. It shuts down the compressor and fan for safety. That is the CH02 error.

Parts and Tools You Will Need

Step-by-Step Fixes

Step 1: Power Cycle the Unit

Unplug the air conditioner from the wall outlet. Wait 10 minutes. Plug it back in. This clears transient errors that sometimes happen during brownouts or power surges.

If the CH02 code goes away and the AC runs normally, the sensor and board are fine. The issue was voltage fluctuation. If the code comes right back, move to Step 2.

Step 2: Check the Thermistor Wiring Connections

Unplug the AC. Remove the front grille and filter. Take off the metal control panel cover. Locate the evaporator coil — the cold finned section at the front of the unit. Follow the two small wires from the coil back to the control board connector.

Look for:

If you find a loose wire, reconnect it firmly. If you see corrosion, cut back to clean wire and use a butt splice connector.

Step 3: Test the Thermistor Resistance

Disconnect the thermistor from the control board. Set your multimeter to resistance (ohms, the Ω symbol). Place one probe on each thermistor wire.

At room temperature (around 77F / 25C), a good thermistor reads approximately 10,000 ohms (10kΩ). The exact reading varies slightly by temperature. Here are typical values:

If your reading is open (OL on the meter) or shorted (0 ohms), the thermistor is bad. If the reading is far outside the expected range (below 2kΩ or above 100kΩ at room temp), the thermistor has drifted out of spec.

Step 4: Replace the Indoor Thermistor

If the thermistor failed the resistance test, replace it.

  1. Unplug the AC
  2. Locate the thermistor embedded in the evaporator coil fins — it looks like a small bead or flat sensor on two wires, sometimes pushed into a metal clip or a plastic holder
  3. Note the routing of the wires so you can run the new one the same way
  4. Cut the old thermistor wires a few inches from the connector
  5. Strip 1/4 inch of insulation from the old wires and the new thermistor wires
  6. Connect using butt splices or wire connectors — match colors (usually both white, but some units use red and black)
  7. Insert the new thermistor bead into the same position on the coil
  8. Route wires away from the fan blade and any moving parts

Step 5: Check the Control Board

If the new thermistor did not fix the error, the control board itself may be at fault. This is less common but happens after a power surge or if the original thermistor shorted and damaged the board.

Before ordering a board:

If the board looks damaged, order an LG control board specific to your model.

Preventing Future CH02 Errors

When to Call a Professional

Call a technician if:


Share this post on: