Temperature sensor
Common error-code part. Confirm resistance and connector style.
Lennox XP21 Heat Pump Error Codes - iComfort Fault Code Guide: likely causes, checks, and repair decisions before replacing parts.
Likely parts to price
Common error-code part. Confirm resistance and connector style.
Useful to price for temperature-reading faults.
Low-cost safety part for heat and no-start symptoms.
Restricted airflow trips high-limit, low-airflow, and frozen-coil faults. Filter King cuts custom sizes if the standard size is out of stock.
Stock a year of filters so the airflow fault does not come back after the fix.
Standard and odd sizes in MERV 8, 11, and 13. Match the MERV your blower is rated for; a filter that is too restrictive trips the same airflow faults as a dirty one.
Wholesale-priced OEM-equivalent parts and full systems shipped direct. Compare before paying contractor markup on a replacement.
Lennox XP21 Heat Pump Error Codes - iComfort Fault Code Guide: likely causes, checks, and repair decisions before replacing parts.
The Lennox XP21 is a variable-capacity heat pump in the Elite series. It uses Lennox’s Quantum Coil and a variable-speed scroll compressor for efficiency ratings up to 21 SEER. The XP21 communicates through the iComfort or Harmony III thermostat system, which displays fault codes and descriptions directly on the thermostat screen. Faults can also be read from the diagnostic LED on the outdoor control board.
| Code | Description |
|---|---|
| 104 | Low-pressure switch open |
| 107 | High-pressure switch open |
| 110 | Defrost sensor fault |
| 126 | Communication error between outdoor and indoor units |
| 204 | Discharge temperature sensor fault |
| 206 | Outdoor ambient temperature sensor fault |
| 227 | Compressor protection device tripped |
| 328 | Variable-speed compressor drive fault |
| 411 | Low-refrigerant charge detected |
| 512 | Outdoor fan motor fault |
| Part | Notes |
|---|---|
| Refrigerant charge (R-410A) | Requires EPA certification; fix leak first |
| Defrost sensor | Clip-on type for outdoor coil |
| Communicating bus wire | 18-gauge two-wire; replace if damaged |
| ECM outdoor fan motor | ECM type; confirm XP21 model compatibility |
| Compressor drive (inverter) | Major part; Lennox dealer required for diagnosis |
| High/low pressure switch | Match to XP21 refrigerant circuit pressures |
For XP21 heat-pump faults, diagnose the iComfort alert and outdoor-unit circuit together: pressure switches, defrost sensors, outdoor thermistors, ECM fan operation, inverter drive status, and communication wiring.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
The XP21’s variable-speed inverter drive and communicating system require Lennox-specific diagnostic software to fully diagnose. Code 328 (drive fault) and repeated Code 411 (low charge) should not be serviced without certified refrigerant handling and inverter knowledge. Contact a Lennox Premier Dealer for advanced diagnostics.