Lennox G60UHV Furnace Error Codes — Flash Code Diagnostic Guide

⚡ Quick Answer

Complete guide to Lennox G60UHV variable-speed furnace error codes, flash sequences, fault causes, and step-by-step repairs for the most common failures.

Lennox G60UHV Furnace Error Codes — What They Mean

The Lennox G60UHV is a variable-speed, 80% AFUE gas furnace that uses an ECM blower motor for quiet, efficient operation. It reports faults through a flashing LED on the control board (SureLight integrated furnace control). The LED flashes a code number, pauses, then repeats. The G60UHV also supports Lennox iComfort and Harmony III communicating thermostat systems, which can display readable fault descriptions.

Jump to Fix

Lennox G60UHV Flash Code Reference

Flash CodeMeaning
1 flashNormal — call for heat satisfied
2 flashesInducer motor not at speed
3 flashesPressure switch stuck open
4 flashesHigh-limit switch open
5 flashesFlame sensed — no call for heat
6 flashesAC power fault (115V)
7 flashesGas valve circuit fault
8 flashesIgnition lockout (failed to prove flame)
9 flashesRollout limit switch open
10 flashesPressure switch stuck closed
11 flashesBlower motor fault
12 flashesLimit device fault (repeated trips)
13 flashesControl board failure

Common Causes by Code

Step-by-Step Fix {#fix}

  1. Read the code — The G60UHV LED is on the lower control board. Open the lower door and note flash count.
  2. For Code 2 — Listen to the inducer motor during startup. It should reach full speed in 15–20 seconds. If it spins slowly or makes noise, check the inducer wheel for debris and confirm the capacitor (if present) is functional.
  3. For Code 3 — Check the condensate trap — it’s integrated into the cabinet on the G60UHV. Remove and flush with water. Check both pressure switch hoses (if two-stage model) for kinks or cracks.
  4. For Code 4 and 12 — Replace the filter. Measure duct static pressure; anything over 0.8” W.C. is too high for the G60UHV. Verify ECM blower speed by confirming full airflow at all registers.
  5. For Code 8 — Confirm SureLight ignitor is glowing during the ignition trial. If no glow, check ignitor resistance (40–90 ohms). If glowing but no flame, check gas valve coil continuity and inlet gas pressure.
  6. For Code 11 — Power cycle the furnace completely. If blower doesn’t run on the next cycle, check the ECM communication connection between the control board and motor. The 5-wire communications plug is a common failure point on early G60UHV units.

Parts Often Needed

PartNotes
SureLight ignitorAmazon | Lennox-specific; use OEM part number
Condensate trapAmazon | Integrated into G60UHV cabinet; replace if cracked
ECM blower moduleAmazon | Mounts to rear of motor; test before replacing motor
Pressure switchAmazon | Confirm correct rating for single or two-stage
Inducer motorAmazon | Replace bearing or full motor assembly
Control boardAmazon | For Code 13 or communication errors

When to Call a Pro

The G60UHV’s ECM motor requires specialized diagnosis. Lennox sells a motor tester tool (L0409MOTORTOOL) used by authorized dealers to identify whether the fault is in the motor, module, or control board. If you’re seeing Code 11 or 13 without an obvious cause, an authorized Lennox dealer can connect diagnostic tools for a definitive diagnosis.