Lennox Error Code 412 Limit Switch Fault

⚡ Quick Answer

Lennox 412 guide for high-limit trips, overheating causes, airflow checks, filters, blower issues, iComfort/SLP faults, and reset limits.

⚡ AT A GLANCEScroll down for full repair guide
What it meansLennox 412 guide for high-limit trips, overheating causes, airflow checks, filters, blower issues, iComfort/SLP faults, and reset limits.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededRun capacitor
Repair intent

Need this fixed instead of diagnosed?

Lennox 412 guide for high-limit trips, overheating causes, airflow checks, filters, blower issues, iComfort/SLP faults, and reset limits.

Likely parts to price

Price the common parts before you book service.

Run capacitor

Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.

Flame sensor

Price this first on furnace ignition faults after cleaning and safety checks.

Igniter

Common furnace start failure part. Confirm connector and model compatibility.

Control board

Higher-cost part to price only after power, sensor, and wiring checks.

Error Code: Lennox 412

What it means: Lennox error code 412 (displayed on the iComfort thermostat or the furnace diagnostic LED as a 4-1-2 flash sequence) indicates an open limit switch circuit. The high limit switch in Lennox SLP, XC, and EL-series furnaces is a normally-closed device mounted on the heat exchanger or supply plenum. It opens when plenum temperature exceeds its calibrated setpoint, typically 160–200°F depending on furnace BTU rating and installation configuration. When the limit opens, the gas valve de-energizes and the blower runs in circulate mode to cool the heat exchanger. Lennox boards log the event and display Code 412.

Common Causes

Diagnosis Steps

  1. Locate and inspect the air filter. Lennox media filters often need replacement every 6–9 months in normal use, not the 12 months marked on the packaging.
  2. Check the iComfort or S30 thermostat for additional fault codes alongside 412. A concurrent blower fault would point to the ECM motor.
  3. Verify all supply/return registers are open and confirm the return air path is unobstructed.
  4. Access the furnace and listen to the blower during heat cycle. Lennox SLP furnaces use variable-speed motors — they should ramp smoothly from low to the appropriate heating speed. Stagnation or low speed suggests ECM module failure.
  5. With power off and furnace cold, measure the limit switch with a multimeter across its terminals. Continuity = normal. OL = switch has failed open and must be replaced.

Fix

Replace the media filter first. If the blower is running at reduced speed, access the ECM module (the rectangular controller attached to the back of the blower motor). Swapping the module is less expensive than replacing the full motor — match the module part number printed on the module housing.

If the limit switch reads open when cold, replace it. Lennox sources its limit switches from several manufacturers — match the temperature rating and physical configuration using the furnace model and serial number.

After correcting the cause, clear the fault via the iComfort thermostat or by cycling furnace power.

Parts

PartWhere to Buy
High limit switchRepairClinic, SupplyHouse
Lennox media filterSupplyHouse
ECM motor moduleRepairClinic, Grainger

Need Replacement Parts?

Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Technician

If Code 412 persists after filter replacement and register correction, have a licensed HVAC tech inspect the heat exchanger. Lennox SLP furnaces are high-efficiency units — a cracked secondary heat exchanger requires professional diagnosis.


Need a professional? Compare HVAC repair options before replacing parts.