Skip to content
Error Code Fixes
Go back
Error code E8

Hoshizaki E8 Error Code - Causes & Fix

3 min read

Independent. We don't sell parts, so we tell you when not to buy one.

⚡ Quick Answer

E8 means bin-thermistor fault: the ice-level sensor is open, shorted, or wired wrong. Replace the bin thermistor or fix the harness.

Difficulty Pro recommended
Est. time 1-3 hrs

Hoshizaki E8 Error Code — What It Means

The E8 error code on a Hoshizaki ice machine signals a bin-thermistor fault. The bin-full sensor (thermistor) is reading out of range, is open-circuited, or is shorted, so the control board cannot correctly detect whether the ice bin is full. The error triggers when the resistance value from the sensor falls outside the manufacturer’s expected window, indicating an electrical failure in the sensor itself or its wiring.

This is distinct from pressure switch faults or defrost thermistor problems, which generate different codes. The machine will not operate normally until the thermistor and its circuit are restored to the correct resistance range.

Before You Replace Anything

Technicians sometimes replace the control board first. Always measure the thermistor resistance and test the wiring harness continuity before condemning the board.

Jump to Fix

Common Causes

Quick Diagnosis

Answer these to narrow it down fast.

Did the E8 code clear after a power cycle and stay gone for at least two full ice cycles?
Yes: The fault was transient. Monitor the machine over the next few days. If it returns, proceed to test the thermistor.
No: The thermistor or its wiring has failed. Continue diagnostics by inspecting connections and measuring resistance.
Does the bin thermistor measure infinite (OL) or zero ohms when you test it with a multimeter?
Yes: The thermistor is open or shorted and must be replaced.
No: Compare the reading to your model's resistance-to-temperature chart. If the value is within spec, test the wiring harness for continuity.
Does the wiring harness show continuity from the thermistor connector to the control board?
Yes: The harness is good. If the thermistor is also within spec, the control board input circuit has likely failed.
No: Repair or replace the wire harness between the sensor and the board.

Step-by-Step Fix

  1. Power off the machine and switch it to the OFF position to safely begin diagnostics.
  2. Locate the bin thermistor mounted in or near the ice storage bin. Trace its wires to the control board and inspect all connections for corrosion, looseness, or visible damage.
  3. Disconnect the thermistor wires from the control board. Using a multimeter set to resistance (ohms), measure across the thermistor terminals.
  4. Compare the resistance reading to the manufacturer’s specification curve for your model. A reading of 0 Ω indicates a short, infinite (OL) indicates an open circuit, and any value far outside the specified range confirms the sensor is defective. Consult your model’s service manual for the exact resistance-to-temperature table.
  5. Test the wiring harness for continuity if the thermistor resistance is within spec. Measure from the sensor connector to the board connector to rule out a broken wire.
  6. Replace the bin thermistor if it is open, shorted, or out of spec. If the harness fails the continuity test, replace the wiring harness.
  7. Reconnect all wiring, restore power, and switch the machine back to ICE mode. Clear the error by cycling the power. Monitor for two full ice cycles to confirm the fault is resolved.

Parts Often Needed

PartNotes
Hoshizaki bin thermistor (ice level sensor)Amazon | Match the part number to your specific model year and series
Thermistor wiring harnessAmazon | Replace if continuity test fails or connector is corroded

When to Call a Pro

Call a commercial refrigeration technician if you are not comfortable working with electrical components or if the thermistor and wiring both test good yet the error persists, indicating a control board fault. Technicians have model-specific resistance charts and can quickly isolate board-level failures. Also call a pro if the machine has refrigerant leaks, compressor issues, or other simultaneous faults that require licensed service.

Rough cost: DIY runs about $30-80 in parts, 30-60 min. A pro service call runs about $150-300.

See Also


🔧 Need a professional? Get free quotes from certified HVAC contractors near you.
Get Free Quotes →
Share this post on:

Previous Post
Hoshizaki E9 Error Code - Causes & Fix
Next Post
Hoshizaki Ice Machine E7 Error - Causes & Fix