Fujitsu Mini Split Ice on Coils - Causes & Fix

3 min read
⚡ Quick Answer

Ice on indoor coils is usually caused by a dirty air filter or clogged evaporator blocking airflow. Clean or replace the filter first.

Difficulty Intermediate (DIY)
Est. time 15-60 min

Fujitsu Mini Split Ice on Coils — What’s Happening

Ice forming on your Fujitsu mini split’s indoor evaporator coil means the coil surface temperature has dropped below freezing, causing moisture in the air to freeze on contact. This happens when something prevents the coil from absorbing enough heat from the room air, or when the refrigerant side is operating incorrectly. If you see an error code displayed along with the ice, E5 is the most common Fujitsu code related to icing. E5 indicates the indoor coil thermistor (temperature sensor) has a short circuit, which means the indoor unit cannot read the evaporator temperature correctly and may not regulate defrost or refrigerant flow properly.

Jump to Fix

Most Likely Causes

How to Diagnose and Fix

  1. Inspect the indoor evaporator coil and copper lines for visible frost or ice buildup.
  2. Check the air filter and replace or clean it if dirty or clogged.
  3. Turn the unit off and allow the coil to defrost completely before further testing.
  4. Remove the front cover and inspect the blower wheel and evaporator coil for dust or debris, and clean if needed.
  5. Verify the indoor fan runs at full speed and delivers strong airflow from the supply vents.
  6. With power off, disconnect the indoor coil thermistor connector and measure the sensor resistance with a multimeter, then compare the reading to the manufacturer’s temperature-resistance chart.
  7. Inspect the thermistor harness and connector for damage, corrosion, loose pins, or moisture intrusion.
  8. If airflow and sensors test good, call a technician to check for refrigerant leaks, verify system charge, and perform refrigerant-side diagnostics including pressure and superheat measurements.

Parts You Might Need

PartNotes
Indoor coil thermistorAmazon | Temperature sensor on the evaporator coil, often triggers E5 code when shorted or open.
Indoor control board / PCBAmazon | Main board for the indoor unit, replace if sensor circuit misreads a good thermistor.
Indoor blower motorAmazon | Fan motor for the air handler, replace if weak or non-functional.
Air filterAmazon | Standard washable or replaceable filter, clean or replace as part of routine maintenance.

If your appliance also shows a code on the display, these match this problem:

When to Call a Pro

Call a professional if the coil continues to ice up after you have cleaned the filter, blower wheel, and evaporator coil and confirmed strong airflow. Refrigerant leaks, charge verification, thermistor testing against factory specs, and indoor board diagnostics require gauges, leak detectors, and model-specific service data. If you see an E5 code or other fault code along with the ice, a technician can test the sensor circuit and replace the thermistor, harness, or control board as needed. Any work involving refrigerant recovery, evacuation, or recharge must be done by an EPA-certified technician.


🔧 Need a professional? Get free quotes from certified HVAC contractors near you.
Get Free Quotes →