Danfoss FC302 ALARM 22 - Causes & Fix

3 min read

What this code means

ALARM 22 on a Danfoss VLT AutomationDrive FC 302 is labeled ‘Hoist mechanical brake.’ The alarm trips when the drive does not reach the expected torque reference within the time set by the hoist or brake control parameters. This is a brake and load condition fault, not an electrical short, earth fault, or communication error.

The drive expects to see torque build up as the brake releases and the motor starts to lift or move the load. If the brake sticks, the load binds, or the torque ramp-up takes too long, the timeout expires and the drive shuts down to protect the hoist system.

Common Causes

Step-by-Step Fix

  1. Verify the brake releases mechanically by securing the load and checking that the brake shoes or disc open fully when power is applied to the brake coil.
  2. Inspect brake wiring and control relay for loose terminals, broken wires, or a failed contactor that may block the release signal from reaching the brake actuator.
  3. Check the drive’s hoist brake parameters in the FC 302 programming menu and confirm the torque reference timeout and ramp settings match the load and brake type.
  4. Test the brake coil resistance and supply voltage to confirm the actuator is energizing properly when the drive commands brake release.
  5. Inspect the hoist load path for binding, damaged cables, worn sheaves, or any mechanical obstruction that would prevent free movement and slow torque buildup.
  6. Clear the alarm from the drive display and perform a controlled start test to verify torque reaches reference before the timeout expires.
  7. Replace the mechanical brake assembly or actuator if inspection reveals worn linings, seized pins, or a failed coil that cannot be repaired in the field.

Parts Often Needed

PartNotes
Hoist mechanical brake assemblyAmazon | For worn or sticking brake shoes, liners, or actuator that will not release cleanly.
Brake coil or electromagnetic actuatorAmazon | When the coil fails electrically and the brake does not open on command.
Brake control relay or contactorAmazon | If the interposing relay in the brake circuit is burned or has welded contacts.

When to Call a Pro

Call a qualified hoist technician or Danfoss-certified drive specialist if you cannot verify brake release, if the alarm persists after replacing the brake components, or if you are unfamiliar with hoist safety lockout and load-test procedures. Hoist applications involve fall hazards and require rigorous lockout-tagout discipline. A professional can also re-tune the drive’s torque ramp and brake timing parameters to match your exact load profile and prevent nuisance trips.

Need this fixed instead? Describe the fault — we'll route it.

Tell us the machine and what it's doing. We read every request and reply by email. Your details go only to our dispatch inbox — see the privacy policy.

Replies come by email. Your details go only to our dispatch inbox — no account, no list.



Previous Post
Danfoss FC302 Alarm 34 - Causes & Fix
Next Post
Danfoss FC302 Alarm 17 - Causes & Fix