Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Amana ASX guide for LED flash codes, pressure-switch faults, compressor overload, control-board faults, thermistors, and low-voltage checks.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Restricted airflow trips high-limit, low-airflow, and frozen-coil faults. Filter King cuts custom sizes if the standard size is out of stock.
Stock a year of filters so the airflow fault does not come back after the fix.
Standard and odd sizes in MERV 8, 11, and 13. Match the MERV your blower is rated for; a filter that is too restrictive trips the same airflow faults as a dirty one.
Wholesale-priced OEM-equivalent parts and full systems shipped direct. Compare before paying contractor markup on a replacement.
Amana ASX guide for LED flash codes, pressure-switch faults, compressor overload, control-board faults, thermistors, and low-voltage checks.
The Amana ASX series (ASX13, ASX14, ASX16) are residential central air conditioners manufactured by Daikin (which owns both Amana and Goodman brands). The ASX uses the same outdoor control board, compressor platform, and flash-code diagnostic system as equivalent Goodman GSX units. If you have an ASX, the flash codes below apply directly — Amana and Goodman share service parts and diagnostic logic across the entire lineup.
| Flash Sequence | Fault |
|---|---|
| 1 flash | Normal — standby |
| 2 flashes | High-pressure switch open |
| 3 flashes | Low-pressure switch open |
| 4 flashes | Compressor protection device open (thermal overload) |
| 5 flashes | Control board fault |
| 6 flashes | Outdoor ambient thermistor fault |
| 7 flashes | Discharge temperature thermistor fault |
| Rapid flash | Low voltage — check 24VAC transformer |
| Part | Notes |
|---|---|
| Dual run capacitor | Most common ASX failure; shared compressor and fan capacitor |
| Contactor | 2-pole; check contact gap and coil pull-in voltage |
| High-pressure switch | Spade terminals; direct swap |
| Low-pressure switch | 50 PSIG cutout for R-410A |
| Ambient thermistor | For Code 6; usually on a pigtail connector |
| Control board | For Code 5; verify fuse and transformer first |
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Refrigerant service on the Amana ASX requires EPA 608 certification and proper manifold gauge equipment. Amana (Daikin/Goodman) offers a Lifetime Compressor Warranty on some ASX models for the original registered homeowner — check warranty status before authorizing a compressor replacement, as the part may be covered at no cost.