A.O. Smith Tankless E20 Error - Causes & Fix

2 min read
⚡ Quick Answer

E20 means the inlet thermistor is shorted. The fix is to replace the inlet temperature sensor or check its wiring and connections.

Difficulty Pro recommended
Est. time 1-3 hrs

A.O. Smith Tankless E20 Error — What It Means

The E20 code on an A.O. Smith electric tankless water heater signals that the inlet thermistor (temperature sensor) has shorted. The manufacturer’s service documentation ties this fault directly to the inlet sensor and directs technicians to replace it rather than attempt a simple reset.

This is not a general overheat or flow issue. It is a specific electrical fault inside the sensor or its wiring. The heater will not operate normally until the shorted component is identified and replaced.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Turn off all power to the unit at the circuit breaker and confirm it is de-energized before opening any panel or touching wiring.
  2. Run hot water through the heater by opening a nearby fixture for about five minutes to stabilize operating conditions for testing.
  3. Locate the inlet thermistor on the inlet water line and inspect its connector and wiring for damage, corrosion, or pinched insulation.
  4. Disconnect and reconnect the thermistor plug firmly to rule out a poor connection, then clear the code and test.
  5. Measure thermistor resistance if you have a multimeter and compare it to the other sensors or consult your model’s service table for acceptable values.
  6. Replace the inlet temperature sensor if resistance is abnormal, the connector shows damage, or the code returns immediately after clearing.
  7. Replace the control board if the E20 fault persists after installing a new inlet thermistor and verifying all connections are secure.

Parts Often Needed

PartNotes
Inlet thermistor / inlet temperature sensorAmazon | Primary replacement part for E20. Match the sensor to your model number.
Control board / circuit boardAmazon | Required if the fault remains after sensor replacement and all wiring checks pass.

When to Call a Pro

Call a licensed technician if you are not comfortable working with live electrical circuits or if you lack a multimeter to verify thermistor resistance. Also contact a pro if the error returns after you have replaced the inlet sensor and inspected all connections. Persistent E20 codes after sensor replacement usually point to a control board fault, and the manufacturer recommends technical support for board-level diagnosis.